Shaking table test of a strengthened full-scale stone masonry building with flexible diaphragms

G Magenes, A Penna, IE Senaldi, M Rota… - International Journal of …, 2014 - Taylor & Francis
An extensive experimental campaign has been conducted at EUCENTRE to understand the
dynamic behavior of historic stone masonry structures and evaluate the seismic …

Numerical assessment of frictional heating in sliding bearings for seismic isolation

V Quaglini, M Bocciarelli, E Gandelli… - Journal of Earthquake …, 2014 - Taylor & Francis
This article proposes a numerical investigation of the frictional heating developed in sliding
bearings under high velocities and the influence of the relevant temperature rise on the …

Assessment of scale effects in the experimental evaluation of the coefficient of friction of sliding isolators

V Quaglini, P Dubini, M Furinghetti… - Journal of Earthquake …, 2022 - Taylor & Francis
Sliding bearings have been extensively used to implement base isolation design in civil
engineering works. Testing of isolators is conducted for characterizing the design properties …

Numerical model of a reinforced concrete building: Earthquake analysis and experimental validation

R Nascimbene - Periodica Polytechnica Civil Engineering, 2015 - pp.bme.hu
Shaking-table experiments of relatively large-scale specimens play a fundamental role in
deepening our understanding of seismic response of existing structures and verification of …

Dynamic Modification and Damage Propagation of a Two‐Storey Full‐Scale Masonry Building

LAS Kouris, A Penna… - Advances in Civil …, 2019 - Wiley Online Library
The progressive change of modal characteristics due to accumulated damage on an
unreinforced masonry (URM) building is investigated. The stone URM building, submitted to …

Eucentre trees lab: laboratory for training and research in earthquake engineering and seismology

S Peloso, A Pavese, C Casarotti - Role of Seismic Testing Facilities in …, 2012 - Springer
Italian awareness about the seismic vulnerability of its building stock dramatically increased
after two earthquakes hit the nation: Umbria-Marche earthquake (1997) and Molise …

[PDF][PDF] Experimental testing of lateral capacity of masonry piers. An application to seismic assessment of AAC masonry buildings

A Costa - Universitat degli Studi di Pavia, 2007 - researchgate.net
The aim of this work was to develop and propose a new experimental test setup to evaluate
the inplane resistance of masonry panels, and also analyse the lateral resistance of …

Analytical modelling of a large‐scale dynamic testing facility

P Ceresa, F Brezzi, GM Calvi… - … Engineering & Structural …, 2012 - Wiley Online Library
An analytical model, which aims at reproducing the response of a large‐scale dynamic
testing facility, that is a system composed of the specimen/shaking table/reaction …

[PDF][PDF] A new large scale laboratory: the LEDA Research Centre (Laboratory of Earthquake engineering and Dynamic Analysis)

M Fossetti, F Lo Iacono, G Minafò… - … on Advances in …, 2017 - researchgate.net
Recently, the field of earthquake engineering experienced substantial enhancements due to
numerous results of experimental and theoretical researches. Modern technical codes …

[PDF][PDF] Shaking-table test on a two-storey RC framed structure with innovative infills with sliding joints

CF Manzini, P Morandi, RR Milanesi… - Proc. 16th …, 2018 - researchgate.net
ABSTRACT Within the European FP7 Project" INSYSME" the research unit of the University
of Pavia conceived a new seismic-resistant masonry infill system allowing the in-plane …