A narrative review on trans-nasal pulmonary aerosol delivery
J Li, JB Fink, R MacLoughlin, R Dhand - Critical Care, 2020 - Springer
The use of trans-nasal pulmonary aerosol delivery via high-flow nasal cannula (HFNC) has
expanded in recent years. However, various factors influencing aerosol delivery in this …
expanded in recent years. However, various factors influencing aerosol delivery in this …
First-time handling of different inhalers by chronic obstructive lung disease patients
Background: There is a lack of guidance on inhaler device selection and how to
individualize inhaler choice when prescribed for the first-time. Aim of the work: To compare …
individualize inhaler choice when prescribed for the first-time. Aim of the work: To compare …
Update efficacy of aerosol therapy with noninvasive ventilator approach (non-invasive ventilation and nasal high flow)
Aerosol delivery by nebulizers and pressurized metered-dose inhalers (pMDIs) attached
through an adapter or spacer into a ventilation circuit during noninvasive mechanical …
through an adapter or spacer into a ventilation circuit during noninvasive mechanical …
Prevalence and predictors of suboptimal peak inspiratory flow rate in COPD patients
The aim of this study was to determine prevalence and possible clinical predictors of
suboptimal peak inspiratory flow rate (PIFR) with different dry powder inhalers. PIFR was …
suboptimal peak inspiratory flow rate (PIFR) with different dry powder inhalers. PIFR was …
The influence of changing interfaces on aerosol delivery within high flow oxygen setting in adults: an in-vitro study
Despite the fact that the nasal-cannula is more comfortable than facemask, using facemask
with high flow oxygen therapy (HFOT) may be beneficial in mouth-breathers. The aim of the …
with high flow oxygen therapy (HFOT) may be beneficial in mouth-breathers. The aim of the …
Aerosol delivery through an adult high-flow nasal cannula circuit using low-flow oxygen
BACKGROUND: There has been a growing trend toward delivering aerosolized medications
using high-flow nasal cannula (HFNC). In some cases, patients who do not require high-flow …
using high-flow nasal cannula (HFNC). In some cases, patients who do not require high-flow …
Effects of fill volume and humidification on aerosol delivery during single-limb noninvasive ventilation
BACKGROUND: The aim of this work was to determine the effect of fill volume and
humidification change on aerosol delivery during single-limb noninvasive ventilation (NIV) …
humidification change on aerosol delivery during single-limb noninvasive ventilation (NIV) …
Modeling and optimization of nebulizers' performance in non-invasive ventilation using different fill volumes: comparative study between vibrating mesh and jet …
Backgrounds Substituting nebulisers by another, especially in non-invasive ventilation (NIV),
involves many process-variables, eg nebulizer-type and fill-volume of respirable-dose …
involves many process-variables, eg nebulizer-type and fill-volume of respirable-dose …
Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation
MHE ElHansy, ME Boules, AFM El Essawy… - Pulmonary …, 2017 - Elsevier
Background Patient receiving invasive mechanical ventilation (IMV) may benefit from
medical aerosol, but guidance on dosing with different aerosol devices is limited to in-vitro …
medical aerosol, but guidance on dosing with different aerosol devices is limited to in-vitro …
Lung deposition and systemic bioavailability of different aerosol devices with and without humidification in mechanically ventilated patients
IOF Moustafa, MRAA Ali, M Al Hallag, H Rabea, JB Fink… - Heart & Lung, 2017 - Elsevier
Background During mechanical ventilation medical aerosol delivery has been reported to be
upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h …
upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h …