Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

S Toupin, P Bour, M Lepetit-Coiffé, V Ozenne… - Journal of …, 2017 - Springer
Background Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA)
currently lacks quantitative and precise visualization of lesion formation in the myocardium …

Quantitative magnetic resonance imaging analysis of the relationship between contact force and left atrial scar formation after catheter ablation of atrial fibrillation

C Sohns, R Karim, J Harrison, A Arujuna… - Journal of …, 2014 - Wiley Online Library
Left Atrial Scar Formation After Contact Force‐Guided AF Ablation Background Catheter
contact force (CF) is an important determinant of radiofrequency (RF) lesion quality during …

Value of magnetic resonance imaging in guiding atrial fibrillation management

FT Han, N Akoum, N Marrouche - Canadian Journal of Cardiology, 2013 - Elsevier
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice today.
Until recently, the therapeutic approaches for AF have been limited by imperfect risk …

Improved cardiac magnetic resonance thermometry and dosimetry for monitoring lesion formation during catheter ablation

V Ozenne, S Toupin, P Bour… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose A new real‐time MR‐thermometry pipeline was developed to measure multiple
temperature images per heartbeat with 1.6× 1.6× 3 mm3 spatial resolution. The method was …

An atrial fibrosis-based approach for atrial fibrillation ablation

FT Han, N Marrouche - Future cardiology, 2015 - Taylor & Francis
Since the emergence of atrial fibrillation (AF) ablation as a reliable method of restoring sinus
rhythm, various approaches have been used to improve the efficacy while maximizing the …

Real-time radiofrequency ablation lesion depth estimation using multi-frequency impedance with a deep neural network and tree-based ensembles

E Besler, YC Wang, AV Sahakian - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Objective: Design and optimization of statistical models for use in methods for estimating
radiofrequency ablation (RFA) lesion depths in soft real-time performance. Methods: Using …

Radiofrequency ablation, MR thermometry, and high-spatial-resolution MR parametric imaging with a single, minimally invasive device

MA Ertürk, S Sathyanarayana Hegde, PA Bottomley - Radiology, 2016 - pubs.rsna.org
Purpose To develop and demonstrate in vitro and in vivo a single interventional magnetic
resonance (MR)–active device that integrates the functions of precise identification of a …

Remotely detuned receiver coil for high-resolution interventional cardiac magnetic resonance imaging

S Marhabaie, M Delcey, D El Hamrani… - Frontiers in …, 2023 - frontiersin.org
Introduction Interventional cardiac MRI in the context of the treatment of cardiac arrhythmia
requires submillimeter image resolution to precisely characterize the cardiac substrate and …

Thin-film micro-coil detectors: Application in MR-thermometry

EM Kardoulaki, RRA Syms, IR Young, M Rea… - Sensors and Actuators A …, 2015 - Elsevier
Thin-film micro-coils are integrated with commercially available ablation catheters, for MR-
thermometry during laser interstitial thermal therapies (LITTs). The coils are formed on a …

The value of magnetic resonance imaging in catheter ablation of atrial fibrillation

J Gu, W Hu, X Liu - Clinical Cardiology, 2015 - Wiley Online Library
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice.
Catheter ablation is now a recognized treatment for those with symptomatic AF refractory to …