Study of impact of bed joint reinforcement on load-carrying capacity and crack resistance of masonry walls made of calcium silicate units

D Łukasz - Journal of Building Engineering, 2021 - Elsevier
This paper presents results from testing eight full-scale walls made of calcium silicate units.
Tested walls were reinforced in the bed joint or unreinforced, with or without openings. The …

Identification of the parameters of Menétrey-Willam failure surface of calcium silicate units

J Radosław - IOP Conference Series: Materials Science and …, 2017 - iopscience.iop.org
The identification of parameters of Menétrey-Willamsurface made of concrete, masonry or
autoclaved aerated concrete is not complicated. It is much more difficult to identify failure …

Proposal of procedure for identification of Menétrey–Willam (MW-3) plasticity surface of homogeneous and hollow masonry units

R Jasiński - Engineering Structures and Technologies, 2019 - jau.vgtu.lt
The article presents the author's proposal to determine the parameters of the Mentérey–
Willam (MW-3) plasticity surface of the homogeneous masonry elements made of …

Analyse von Spannungen und Verformungen im Brüstungsbereich von Wandmodellen aus Porenbeton und Kalksandstein

Ł Drobiec - Mauerwerk, 2020 - Wiley Online Library
In dem vorliegenden Beitrag wurden Ergebnisse der Prüfungen von großformatigen
Wandmodellen mit zwei Fensteröffnungen dargestellt. Wände aus Porenbeton und …

Failure of a warehouse floor by subsoil settlement

S Kwiecień - MATEC Web of Conferences, 2019 - matec-conferences.org
This paper discusses the failure of a warehouse floor (with an approximate surface area of
1.550 m 2) inside an industrial building with a total developed area of approx. 8.200 m 2 …

Experimental and Numerical Analysis of the Quasi-Static and Dynamic Behavior of Silicate Materials

T Jankowiak, JR Ossowski, A Rusinek, S Bahi - 2024 - preprints.org
The study investigated both the static and dynamic behavior of silicate materials through a
series of experimental and numerical tests. Compression tests were conducted on cubic …

Stress‐strain analysis in the window zone area of full‐scale wall models made of AAC and calcium silicate units

Ł Drobiec - Civil Engineering Design, 2019 - Wiley Online Library
This article presents results of tests on full‐scale wall models with two window openings.
Tested walls were made of autoclaved aerated concrete (AAC) units and calcium‐silicate (C …

Commercial building flooring failure caused by swelling of the foundation layers

S Kwiecień - MATEC Web of Conferences, 2019 - matec-conferences.org
The work describes the damage, testing and method of repairing the flooring. The flooring
formed part of a commercial pavilion covering an area of approx. 1200 m 2. Significant …

[PDF][PDF] Shear and Flexural Strength of Masonry Walls Made of Calcium Silicate Materials Made in Poland

R Jasiński, A Piekarczyk, Ł Drobiec - 2018 - researchgate.net
In the article are presented the results of the shear and flexural strength of the masonry
specimens with the thin joints made of 15 types of the calcium-silicate masonry units …

[PDF][PDF] PROPOZYCJA IDENTYFIKACJI PARAMETRÓW POWIERZCHNI PLASTYCZNOŚCI MENÉTREY'A-WILLAMA JEDNORODNYCH I PIONOWO DRĄŻONYCH …

R JASIŃSKI - researchgate.net
W numerycznych analizach konstrukcji murowych stosować można zróżnicowaną metodykę
postępowania. W zastosowaniach inżynierskich, które dopuszczają aktualne normy …