Adaptive DC-link voltage control of two-stage photovoltaic inverter during low voltage ride-through operation

G Ding, F Gao, H Tian, C Ma, M Chen… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper proposes an adaptive dc-link voltage control method for the two-stage
photovoltaic inverter during the low voltage ride-through (LVRT) operation period. The dc …

Active power filter: review of converter topologies and control strategies

L Sarıbulut, A Teke, M Meral… - Gazi university journal of …, 2011 - dergipark.org.tr
Decrease in the cost of power electronic devices and improvement in the efficiency of both
power converters and energy storage components have increased the applicability of new …

Detection of grid voltage fundamental and harmonic components using Kalman filter and generalized averaging method

A Bagheri, M Mardaneh, A Rajaei… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
The proper operation of single-phase and three-phase grid-connected power converters
depends on the synchronization with utility networks. The major challenge of the …

A grid fundamental and harmonic component detection method for single-phase systems

YF Wang, YW Li - IEEE Transactions on Power Electronics, 2012 - ieeexplore.ieee.org
Single-phase grid-connected converters are widely used in many applications such as
photovoltaics, fuel cells, active power filters, etc. An important topic for the development of …

Hybrid If starting and observer-based sensorless control of single-phase BLDC-PM motor drives

LI Iepure, I Boldea, F Blaabjerg - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
A motion sensorless control for single-phase permanent magnet brushless dc motor based
on an If starting sequence and a real-time permanent magnet flux estimation is proposed …

An Efficient Technique Using Modified p–q Theory for Controlling Power Flow in a Single-Stage Single-Phase Grid-Connected PV System

A Datta, R Sarker, I Hazarika - IEEE Transactions on Industrial …, 2018 - ieeexplore.ieee.org
In this paper, an efficient power conditioning unit is presented for a single-phase grid-
connected photovoltaic (PV) system incorporating both maximum power-point tracking and …

Stability analysis and performance evaluation of a single‐phase phase‐locked loop algorithm using a non‐autonomous adaptive filter

VD Bacon, SA Oliveira da Silva… - IET Power …, 2014 - Wiley Online Library
This study proposes a phase‐locked loop (PLL) algorithm employed for phase‐angle
detection of single‐phase utility grid voltage. A detailed stability analysis is performed, as …

A voltage detection method for the voltage ride-through operation of renewable energy generation systems under grid voltage distortion conditions

C Ma, F Gao, G He, G Li - IEEE Transactions on Sustainable …, 2014 - ieeexplore.ieee.org
This paper proposes a new voltage detection method to assist the low-voltage ride-through
operation of grid-tied converters. In particular, it consists of one synchronous reference …

Analysis and design of a digital phase-locked loop for single-phase grid-connected power conversion systems

Q Zhang, XD Sun, YR Zhong… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
A new digital phase-locked-loop (DPLL) method is proposed for single-phase grid-
connected power conversion systems in this paper. The analysis of a phase detector using …

Active harmonic filters: Control techniques review

D Schwanz, A Bagheri, M Bollen… - 2016 17th International …, 2016 - ieeexplore.ieee.org
The use of active filters for harmonic mitigation compensation is increasing together with the
improvement of their control techniques. Depending on the situation, the use of one …