Recent advances in parallel imaging for MRI

J Hamilton, D Franson, N Seiberlich - Progress in nuclear magnetic …, 2017 - Elsevier
Abstract Magnetic Resonance Imaging (MRI) is an essential technology in modern
medicine. However, one of its main drawbacks is the long scan time needed to localize the …

Reducing sedation for pediatric body MRI using accelerated and abbreviated imaging protocols

R Ahmad, HH Hu, R Krishnamurthy, R Krishnamurthy - Pediatric radiology, 2018 - Springer
Magnetic resonance imaging (MRI) is an established diagnostic imaging tool for
investigating pediatric disease. MRI allows assessment of structure, function, and …

Whole‐heart spiral simultaneous multi‐slice first‐pass myocardial perfusion imaging

Y Yang, CH Meyer, FH Epstein… - Magnetic resonance …, 2019 - Wiley Online Library
Purpose To develop and evaluate a simultaneous multislice (SMS) spiral perfusion pulse
sequence with whole‐heart coverage. Methods An orthogonal set of phase cycling angles …

Simple auto‐calibrated gradient delay estimation from few spokes using Radial Intersections (RING)

S Rosenzweig, HCM Holme… - Magnetic resonance in …, 2019 - Wiley Online Library
Purpose To develop a simple and robust tool for the estimation of gradient delays from
highly undersampled radial k‐space data. Theory In radial imaging gradient delays induce …

Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath‐hold

S Weingärtner, S Moeller, S Schmitter… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To develop a saturation recovery myocardial T1 mapping method for the
simultaneous multislice acquisition of three slices. Methods Saturation pulse‐prepared heart …

Deep learning for radial SMS myocardial perfusion reconstruction using the 3D residual booster U-net

J Le, Y Tian, J Mendes, B Wilson, M Ibrahim… - Magnetic resonance …, 2021 - Elsevier
Purpose To develop an end-to-end deep learning solution for quickly reconstructing radial
simultaneous multi-slice (SMS) myocardial perfusion datasets with comparable quality to the …

[HTML][HTML] Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative …

MS Nazir, R Neji, P Speier, F Reid, D Stäb… - Journal of …, 2018 - Elsevier
Abstract Background Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to
acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial …

Improved Simultaneous Multi-slice imaging with Composition of k-space Interpolations (SMS-COOKIE) for myocardial T1 mapping

ÖB Demirel, S Weingärtner, S Moeller, M Akçakaya - PloS one, 2023 - journals.plos.org
The aim of this study is to develop and evaluate a regularized Simultaneous Multi-Slice
(SMS) reconstruction method for improved Cardiac Magnetic Resonance Imaging (CMR) …

Combined simultaneous multislice bSSFP and compressed sensing for first‐pass myocardial perfusion at 1.5 T with high spatial resolution and coverage

S McElroy, G Ferrazzi, MS Nazir… - Magnetic resonance …, 2020 - Wiley Online Library
Purpose To implement and evaluate a pseudorandom undersampling scheme for combined
simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) …

Simultaneous multi‐slice MRI using cartesian and radial FLASH and regularized nonlinear inversion: SMS‐NLINV

S Rosenzweig, HCM Holme, RN Wilke… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose The development of a calibrationless parallel imaging method for accelerated
simultaneous multi‐slice (SMS) MRI based on Regularized Nonlinear Inversion (NLINV) …