Transvenous lead extraction in conduction system pacing

N Wijesuriya, MK Elliott, V Mehta, JM Behar… - Frontiers in …, 2022 - frontiersin.org
Conduction System Pacing (CSP) delivered by His Bundle Pacing (HBP) or Left Bundle
Pacing (LBP) are exciting novel interventions in the field of Cardiac Resynchronization …

Conduction system pacing versus conventional biventricular pacing for cardiac resynchronization therapy: where are we heading?

G Domenichini, M Le Bloa, C Teres Castillo… - Journal of Clinical …, 2023 - mdpi.com
Over the last few years, pacing of the conduction system (CSP) has emerged as the new
standard pacing modality for bradycardia indications, allowing a more physiological …

[HTML][HTML] Conduction system pacing learning curve: Left bundle pacing compared to His bundle pacing

M O'Connor, R Shi, DB Kramer, O Riad… - IJC Heart & …, 2023 - Elsevier
Introduction Conduction system pacing (CSP), consisting of His bundle pacing (HBP) or left
bundle branch area pacing (LBBAP) is a rapidly developing field. These pacing techniques …

Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience

F Migliore, R Pittorru, M De Lazzari, V Tarzia… - Journal of Interventional …, 2024 - Springer
Abstract Background The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic,
Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However …

Paradigm Shifts in Cardiac Pacing: Where Have We Been and What Lies Ahead?

BA Ballantyne, DS Chew, B Vandenberk - Journal of Clinical Medicine, 2023 - mdpi.com
The history of cardiac pacing dates back to the 1930s with externalized pacing and has
evolved to incorporate transvenous, multi-lead, or even leadless devices. Annual …

Extraction of a fractured pacemaker lead in the left bundle branch area using a snare via a femoral approach

CA Agudo, EGI Jaén, DJ Sánchez, VC Urda… - Journal of Interventional …, 2023 - Springer
We present the first reported case of extraction of a ventricular lead placed in the left bundle
branch area with a double-loop design snare via the femoral approach without any …

Extraction of His Bundle Pacing Lead: More Difficult than Coronary Sinus Lead Extraction: An Analysis of 3897 Lead Extraction Procedures Including 27 His and 253 …

P Stefańczyk, W Jacheć, A Kutarski, P Dąbrowski… - Biomedicines, 2024 - mdpi.com
Background: Experience with the transvenous extraction of leads used for His bundle pacing
(HBP) is limited. Methods: Analysis of 3897 extractions including 27 HBP and 253 LVP (left …

Left-bundle branch pacing as bail-out strategy after failed coronary sinus lead placement for cardiac resynchronization: a case report

T Fink, T Eitz, C Sohns, P Sommer… - … Heart Journal-Case …, 2022 - academic.oup.com
Background Cardiac resynchronization therapy (CRT) by implantation of an endocardial
coronary sinus (CS) pacing lead is an established heart failure therapy. The recent …

Extraction of lumen less pacing leads from the His Bundle and left bundle branch area–outcomes of the high volume center

R Gardas, D Loboda, J Biernat, T Soral, P Kulesza… - Europace, 2024 - academic.oup.com
Background and aims The application of conduction system pacing (CSP) in clinical practice
is growing, and the need for lead extraction will also increase. The data on outcomes and …

[PDF][PDF] Prevenzione, diagnosi e trattamento delle infezioni dei dispositivi cardiaci elettronici impiantabili. Position paper dell'Associazione Italiana di Aritmologia e …

E Pisanò, G Mitacchione, A Pappalardo, A Di Grazia… - G Ital Cardiol, 2023 - aiac.it
The number of cardiac implantable electronic device (CIED) implantations has increased
over recent years as a result of population growth, increasing life expectancy, adoption of …