[HTML][HTML] Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: an updated meta-analysis
Y Zhao, K Yang, J Li, Y Huang, S Zhu - Medicine, 2017 - journals.lww.com
Background: Posterior capsular opacification (PCO) is a common long-term complication of
cataract surgery. Intraocular lens design and material have been implicated in influencing …
cataract surgery. Intraocular lens design and material have been implicated in influencing …
Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery
S Maedel, JR Evans, A Harrer-Seely… - Cochrane Database of …, 2021 - cochranelibrary.com
Background Posterior capsule opacification (PCO) is a clouding of the posterior part of the
lens capsule, a skin‐like transparent structure, which surrounds the crystalline lens in the …
lens capsule, a skin‐like transparent structure, which surrounds the crystalline lens in the …
Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery
Purpose: To analyze the characteristics and factors associated with intraocular lens (IOL) tilt
and decentration after uneventful phacoemulsification with IOL implantation. Setting …
and decentration after uneventful phacoemulsification with IOL implantation. Setting …
[HTML][HTML] Effect of hydrophobic acrylic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: meta-analysis
Purpose This meta-analysis aims to evaluate the differences in performance of posterior
capsular opacification (PCO) between hydrophobic acrylic intraocular lens (IOLs) and …
capsular opacification (PCO) between hydrophobic acrylic intraocular lens (IOLs) and …
Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation
N Hirnschall, PC Hoffmann, P Draschl… - Journal of Refractive …, 2014 - journals.healio.com
PURPOSE: To evaluate the influencing factors on remaining astigmatism after implanting a
toric intraocular lens during cataract surgery. METHODS: In this observational study …
toric intraocular lens during cataract surgery. METHODS: In this observational study …
Different‐sized incisions for phacoemulsification in age‐related cataract
C Jin, A Law, Y Kang, X Wang, W Xu… - Cochrane Database of …, 2017 - cochranelibrary.com
Background Age‐related cataract is the principal cause of blindness and visual impairment
in the world. Phacoemulsification is the main surgical procedure used to treat cataract. The …
in the world. Phacoemulsification is the main surgical procedure used to treat cataract. The …
Rotational stability of a single-piece toric acrylic intraocular lens: a pilot study
N Hirnschall, S Maedel, M Weber, O Findl - American Journal of …, 2014 - Elsevier
Purpose To evaluate the visual performance and rotational stability of the Tecnis Toric 1-
piece intraocular lens (IOL) during the first 3 postoperative months. Design Prospective …
piece intraocular lens (IOL) during the first 3 postoperative months. Design Prospective …
[HTML][HTML] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
Q Wu, Y Li, L Wu, CY Wang - International Journal of …, 2022 - ncbi.nlm.nih.gov
AIM To conduct a Meta-analysis pooling randomized controlled trials (RCTs) to compare
hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule …
hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule …
Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling
L Remón, D Siedlecki, I Cabeza-Gil… - Journal of Biomedical …, 2018 - spiedigitallibrary.org
Intraocular lenses (IOLs) are used in the cataract treatment for surgical replacement of the
opacified crystalline lens. Before being implanted they have to pass the strict quality control …
opacified crystalline lens. Before being implanted they have to pass the strict quality control …
A meta-analysis of Nd: YAG capsulotomy rates for two hydrophobic intraocular lens materials
M Von Tress, JS Marotta, SS Lane… - Clinical …, 2018 - Taylor & Francis
Purpose The purpose of this study is to estimate and compare neodymium-doped yttrium
aluminum garnet (Nd: YAG) capsulotomy rates for AcrySof® and Clareon® intraocular lens …
aluminum garnet (Nd: YAG) capsulotomy rates for AcrySof® and Clareon® intraocular lens …