[HTML][HTML] Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testing–Part II

K Wang, E Kenanidis, M Miodownik, E Tsiridis… - Clinical …, 2019 - Elsevier
Background Periprosthetic femoral fracture is a severe complication of total hip arthroplasty.
A previous review published in 2011 summarised the biomechanical studies regarding …

Biomechanics of total hip arthroplasty

E Tokgöz - Total hip arthroplasty: Medical and biomedical …, 2022 - Springer
Biomechanics of total hip arthroplasty (THA) is one of the areas where physiology,
engineering, and physics meet. In this article, we will cover biomechanical impacts of …

Periprosthetic fracture fixation in osteoporotic bone

M Lenz, W Lehmann, D Wähnert - Injury, 2016 - Elsevier
Fixation techniques of periprosthetic fractures are far from ideal although the number of this
entity is rising. The presence of an intramedullary implant generates its own fracture …

Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study

M Miura, J Nakamura, Y Matsuura, Y Wako… - BMC musculoskeletal …, 2017 - Springer
Background Finite element analysis (FEA) of the proximal femur has been previously
validated with large mesh size, but these were insufficient to simulate the model with small …

Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients

WR Smith, JW Stoneback, SJ Morgan, PF Stahel - Patient safety in surgery, 2016 - Springer
Background Periprosthetic distal femur fractures associated with total knee replacement are
increasing in incidence. We hypothesized that a standardized management protocol would …

A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation

R Dhason, S Roy, S Datta - Computer Methods and Programs in …, 2020 - Elsevier
Background and objectives Composite bone plates are proposed for fracture fixation in
periprosthetic femoral fracture. Metallic plates, having high stiffness compared to bone lead …

Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur

M Heyland, GN Duda, NP Haas, A Trepczynski… - Injury, 2015 - Elsevier
Background Extent and orientation of interfragmentary movement (IFM) are crucially
affecting course and quality of fracture healing. The effect of different configurations for …

Hip revision arthroplasty for failed osteosynthesis in periprosthetic Vancouver type B1 fractures using a cementless, modular, tapered revision stem

B Fink, D Oremek - The Bone & Joint Journal, 2017 - boneandjoint.org.uk
Aims To evaluate the hypothesis that failed osteosynthesis of periprosthetic Vancouver type
B1 fractures can be treated successfully with stem revision using a transfemoral approach …

Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation–a biomechanical study

K Gordon, M Winkler, T Hofstädter, U Dorn, P Augat - Injury, 2016 - Elsevier
With increasing life expectancy and number of total hip arthroplasties (THA), the need for
revision surgery is increasing too. The aim of this study was to evaluate the optimal fracture …

Application of far cortical locking technology in periprosthetic femoral fracture fixation: a biomechanical study

M Moazen, A Leonidou, J Pagkalos, A Marghoub… - The Journal of …, 2016 - Elsevier
Background Lack of fracture movement could be a potential cause of periprosthetic femoral
fracture (PFF) fixation failures. This study aimed to test whether the use of distal far cortical …