Evaluation of feeder monitoring parameters for incipient fault detection using Laplace trend statistic
CJ Kim, SJ Lee, SH Kang - 38th IAS Annual Meeting on …, 2003 - ieeexplore.ieee.org
This paper focuses on a systematic and cumulative statistical approach for identifying
symptom parameters of incipient faults in distribution feeders. The proposed method aims to …
symptom parameters of incipient faults in distribution feeders. The proposed method aims to …
Experimental techniques to simulate naturally polluted high voltage transmission line insulators
OE Gouda, AZ El Dein - IEEE Transactions on Dielectrics and …, 2014 - ieeexplore.ieee.org
This paper represents experimental techniques to simulate the naturally polluted high
voltage insulators, under conditions that simulate the desert environment. Usually, the IEC …
voltage insulators, under conditions that simulate the desert environment. Usually, the IEC …
A new monitor for pollution on power line insulators. Part 2: Simulated field tests
An apparatus is developed for monitoring the leakage currents drawn by an insulator chain
of a power line or a busbar support in a polluted atmosphere. The apparatus monitors the …
of a power line or a busbar support in a polluted atmosphere. The apparatus monitors the …
A study on the characterization of the incipient failure behavior of insulators in power distribution line
CJ Kim, JH Shin, MH Yoo… - IEEE Transactions on …, 1999 - ieeexplore.ieee.org
A feasibility study on the characterization of incipient insulator failure for distribution fault
prediction is presented. In this study, real distribution data was collected and analyzed to …
prediction is presented. In this study, real distribution data was collected and analyzed to …
Relation between leakage impedance and equivalent salt deposit density on an insulator under a saltwater spray
H Matsuo, T Fujishima, T Yamashita… - IEEE transactions on …, 1999 - ieeexplore.ieee.org
The degree of pollution of an insulator polluted rapidly under a saltwater spray is observed
by measurement of the leakage current, which flows between electrodes fixed on the surface …
by measurement of the leakage current, which flows between electrodes fixed on the surface …
Laboratory simulation of naturally polluted high‐voltage transmission line insulators
OE Gouda, AZ El Dein - IET Generation, Transmission & …, 2014 - Wiley Online Library
This study represents experimental techniques for testing the high‐voltage polluted
insulators under conditions simulating the natural environment. International …
insulators under conditions simulating the natural environment. International …
Optical monitor for contamination on HV insulator surfaces
F Mahmoud, RMA Azzam - IEEE transactions on dielectrics and …, 1997 - ieeexplore.ieee.org
Ellipsometry is used to monitor naturally deposited contamination films on HV electrical
power insulators that are used in overhead transmission lines and substations. Good …
power insulators that are used in overhead transmission lines and substations. Good …
Study the Relationship between the Resistance and ESDD of A Contaminated insulator A Laboratory Approach
MA Salam, K Aamer, A Hamdan… - Proceedings of the 7th …, 2003 - ieeexplore.ieee.org
The level of contamination on the surface of the insulator is represented by the Equivalent
Salt Deposit Density. In the laboratory, two types of salts (NaCl, CuSO/sub 4/) with different …
Salt Deposit Density. In the laboratory, two types of salts (NaCl, CuSO/sub 4/) with different …
Design and construction of a pollution monitor for power line insulators
J Ramirez-Nino, MJO Pacheco… - Measurement …, 1996 - iopscience.iop.org
The basics of insulators' pollution processes are first reviewed, including the main physical
and chemical factors involved. A novel fibre-optic-based device for measuring leakage and …
and chemical factors involved. A novel fibre-optic-based device for measuring leakage and …
Smart pH sensor for condition monitoring of insulators in the smart grid
AA Khan, M Rihan - ISGT2011-India, 2011 - ieeexplore.ieee.org
The interconnected nature of the power system makes economical use of the power
generated and generally improves overall reliability. However, this increase in reliability …
generated and generally improves overall reliability. However, this increase in reliability …