Analysis, design and digital implementation of a shunt active power filter with different schemes of reference current generation

SK Chauhan, MC Shah, RR Tiwari… - IET Power …, 2014 - Wiley Online Library
To reduce the harmonics injected by non‐linear loads, power quality improvement devices
like shunt active power filters (SAPFs) are commonly employed. This study presents a digital …

Current error space phasor based hysteresis controller for two-level and three-level converters used in shunt active power filters

SK Chauhan, PN Tekwani - IECON 2013-39th Annual …, 2013 - ieeexplore.ieee.org
Shunt Active Power Filters (SAPF) are commonly employed to reduce current harmonics,
which are injected in the utility by nonlinear loads. This paper presents performance of …

[PDF][PDF] Cascaded Three Level Inverter Based Shunt Active Power Filter with Modified Three Level Hysteresis Current Control

J Pandya, R Jadeja, T Trivedi - International Review on Modelling …, 2018 - researchgate.net
A Cascaded three level inverter is controlled by using a three level HCC technique. The
method has certain advantages compared to a two level HCC, such as a reduced switching …

A Novel Hybrid Switching Scheme based Implementation of Shunt Active Power Filter

A Chandwani, A Mallik - … 2020 The 46th Annual Conference of …, 2020 - ieeexplore.ieee.org
Shunt Active Power Filters (SAPF) are universally used to curtail current harmonics
appearing in the utility grids due to abundance of non-linear loads. This paper elucidates a …

Analysis, design and simulation of three-phase active power filter with series capacitor topology for current harmonic compensation

N Pandya, PN Tekwani, V Patel - International Journal of …, 2018 - inderscienceonline.com
The proposed system consists of an LC passive filter connected in series with three-phase
active power filter. The passive filter is tuned to 13th order harmonic frequency. Major portion …

Current error space phasor based hystersis controller applied to Bi-directional front-end boost-converter for unity power factor and low THD

MT Shah, PN Tekwani - 2014 IEEE International Conference on …, 2014 - ieeexplore.ieee.org
Three-phase pulse width modulated (PWM) front-end converter (FEC) has now become an
essential part of many power electronic systems such as uninterruptible power supplies …

Improved Quality of Compensation in Three-Level Shunt Active Power Filter Using Fractal Approach Based Current Hysteresis Controller

SK Chauhan, MT Shah… - IECON 2021–47th Annual …, 2021 - ieeexplore.ieee.org
Current error space phase based hysteresis controlled shunt active power filter (SAPF)
requires two (inner and outer) hysteresis bands for vector selection and for sector detection …

[PDF][PDF] Experimental Evaluation of Time Harmonic Detection Methods for Shunt Active Power Filter

H Tédjini, Y Meslem, M Guichiche… - International Review of …, 2013 - researchgate.net
The active power filters, APFs, can be used as a practical solution to solve the problems
caused by the lack of electric power quality. One of the most discussed software part (in the …

[引用][C] Operation and analysis of float cum boost charger in high-voltage switchgear backup system

F Mohammadi - The first international conference on modern …, 2018