Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysis
Background Transvenous lead extraction (TLE) is a complex invasive procedure and the
experience of the operator and the team is a major determinant of procedural outcomes. Aim …
experience of the operator and the team is a major determinant of procedural outcomes. Aim …
[HTML][HTML] Neointimal fibrotic lead encapsulation–Clinical challenges and demands for implantable cardiac electronic devices
J Keiler, M Schulze, M Sombetzki, T Heller, T Tischer… - Journal of …, 2017 - Elsevier
Every tenth patient with a cardiac pacemaker or implantable cardioverter-defibrillator
implanted is expected to have at least one lead problem in his lifetime. However …
implanted is expected to have at least one lead problem in his lifetime. However …
[图书][B] Cardiac pacing and ICDs
KA Ellenbogen, K Kaszala - 2014 - books.google.com
Cardiac Pacing and ICDs, 6e is the ideal resource for clinicians who need an accessible,
clinically-focused guide to cardiac pacemakers, ICDs and CRTs. Completely updated, and …
clinically-focused guide to cardiac pacemakers, ICDs and CRTs. Completely updated, and …
Ultrasound-guided arterial access: outcomes among patients with peripheral artery disease and critical limb ischemia undergoing peripheral interventions.
JA Mustapha, LJ Diaz-Sandoval, MR Jaff… - The Journal of …, 2016 - europepmc.org
Objective Arterial cannulation is a vital component of endovascular interventions and often
unconventional access approaches are required due to disease complexity. Historically …
unconventional access approaches are required due to disease complexity. Historically …
Multicenter experience with transvenous lead extraction of active fixation coronary sinus leads
M Maytin, RG Carrillo, P Baltodano… - Pacing and clinical …, 2012 - Wiley Online Library
Background/Objective: Active fixation coronary sinus (CS) leads limit dislodgement and
represent an attractive option to the implanter. Although extraction of passive fixation CS …
represent an attractive option to the implanter. Although extraction of passive fixation CS …
Outcomes and predictors of difficulty with coronary sinus lead removal
S Sheldon, PA Friedman, DL Hayes, MJ Osborn… - Journal of interventional …, 2012 - Springer
With increasing coronary sinus (CS) pacemaker leads for cardiac resynchronization therapy,
the need to remove these leads has risen. The purpose of this study is to describe a single …
the need to remove these leads has risen. The purpose of this study is to describe a single …
Cardiac venous left ventricular lead removal and reimplantation following device infection: a large single‐center experience
J Rickard, K Tarakji, E Cronin… - Journal of …, 2012 - Wiley Online Library
LV Lead Extraction and Reimplantation. Background: Early series of biventricular device
removal have contained mostly younger cardiac venous (CV) left ventricular leads and few …
removal have contained mostly younger cardiac venous (CV) left ventricular leads and few …
Prolonged lead dwell time and lead burden predict bailout transfemoral lead extraction
J Gould, BS Sidhu, B Porter… - Pacing and Clinical …, 2019 - Wiley Online Library
Background Transvenous lead extraction (TLE) may be performed by superior approach
using the original implant vein or via a femoral approach; however, limited comparative data …
using the original implant vein or via a femoral approach; however, limited comparative data …
Transvenous lead extraction in patients with cardiac resynchronization therapy devices is not associated with increased 30-day mortality
J Gould, M Klis, B Porter, BJ Sieniewicz, BS Sidhu… - EP …, 2019 - academic.oup.com
Aims Transvenous lead extraction (TLE) may be necessary due to system infection/erosion
or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may …
or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may …
Safety and effectiveness of transvenous lead extraction in patients with infected Cardiac Resynchronization Therapy Devices; Is it more risky than extraction of other …
P Stefańczyk, D Nowosielecka, A Polewczyk… - International Journal of …, 2022 - mdpi.com
Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter
defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as …
defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as …