Closed loop automated oxygen control in neonates—A review

S Sturrock, E Williams, T Dassios… - Acta Paediatrica, 2020 - Wiley Online Library
Aim Neonates frequently require supplementary oxygen but may develop complications if
the oxygen saturation is outside the target range. This review aimed to determine whether …

Automated oxygen control in preterm infants, how does it work and what to expect: a narrative review

HH Salverda, SJE Cramer, RSGM Witlox… - Archives of Disease in …, 2021 - fn.bmj.com
Background Automated oxygen control systems are finding their way into contemporary
ventilators for preterm infants, each with its own algorithm, strategy and effect. Objective To …

The effect of automated oxygen control on clinical outcomes in preterm infants: a pre-and post-implementation cohort study

HH Salverda, NJ Oldenburger, M Rijken… - European journal of …, 2021 - Springer
Several studies demonstrated an increase in time spent within target range when automated
oxygen control (AOC) is used. However the effect on clinical outcome remains unclear. We …

Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support

GK Plottier, KI Wheeler, SKM Ali, OS Fathabadi… - Archives of Disease in …, 2017 - fn.bmj.com
Objective To evaluate the performance of a novel rapidly responsive proportional-integral-
derivative (PID) algorithm for automated oxygen control in preterm infants with respiratory …

Automation of oxygen titration in preterm infants: current evidence and future challenges

PA Dargaville, AP Marshall, L McLeod… - Early human …, 2021 - Elsevier
For the preterm infant with respiratory insufficiency requiring supplemental oxygen, tight
control of oxygen saturation (SpO 2) is advocated, but difficult to achieve in practice …

Automated control of inspired oxygen (FiO2) in preterm infants: Literature review

C Dani - Pediatric Pulmonology, 2019 - Wiley Online Library
Abstract The vast majority (95%) of very preterm infants receive oxygen‐therapy monitored
by oxygen pulse saturation (SpO2). However, they spend a significant percentage of time …

The effect of implementing an automated oxygen control on oxygen saturation in preterm infants

HA Van Zanten, K Kuypers, BJ Stenson… - Archives of Disease in …, 2017 - fn.bmj.com
Objective To evaluate the effect of implementing automated oxygen control as routine care
in maintaining oxygen saturation (SpO 2) within target range in preterm infants. Methods …

Development and preclinical testing of an adaptive algorithm for automated control of inspired oxygen in the preterm infant

PA Dargaville, OS Fathabadi, GK Plottier… - Archives of Disease in …, 2017 - fn.bmj.com
Objective To assess the performance of a novel algorithm for automated oxygen control
using a simulation of oxygenation founded on in vivo data from preterm infants. Methods A …

Automated control of oxygen titration in preterm infants on non-invasive respiratory support

PA Dargaville, AP Marshall, OJ Ladlow… - Archives of Disease in …, 2022 - fn.bmj.com
Objective To evaluate the performance of a rapidly responsive adaptive algorithm (VDL1. 1)
for automated oxygen control in preterm infants with respiratory insufficiency. Design …

Experimental low cost reflective type oximeter for wearable health systems

EMG Rodrigues, R Godina, CMP Cabrita… - … Signal Processing and …, 2017 - Elsevier
The advent of wearable technology is fundamental to the dissemination of wearable
personal health monitoring devices. Recent developments of biomedical sensors have …