Dose–volume constraints fOr oRganS At risk In Radiotherapy (CORSAIR): an “All-in-One” multicenter–multidisciplinary practical summary
S Bisello, S Cilla, A Benini, R Cardano, NP Nguyen… - Current …, 2022 - mdpi.com
Background: The safe use of radiotherapy (RT) requires compliance with dose/volume
constraints (DVCs) for organs at risk (OaRs). However, the available recommendations are …
constraints (DVCs) for organs at risk (OaRs). However, the available recommendations are …
Evaluation of the feasibility of cardiac gating for SBRT of ventricular tachycardia based on real‐time ECG signal acquisition
CQM Reis, JL Robar - Journal of Applied Clinical Medical …, 2023 - Wiley Online Library
Purpose To investigate the feasibility of cardiac synchronized gating in stereotactic body
radiation therapy (SBRT) of ventricular tachycardia (VT) using a real‐time electrocardiogram …
radiation therapy (SBRT) of ventricular tachycardia (VT) using a real‐time electrocardiogram …
Static couch non-coplanar arc selection optimization for lung SBRT treatment planning
JD Lincoln, RL MacDonald, A Syme… - Physics in Medicine & …, 2023 - iopscience.iop.org
Objective. Non-coplanar arc geometry optimizations that take advantage of beam's eye view
(BEV) geometric overlap information have been proven to reduce dose to healthy organs-at …
(BEV) geometric overlap information have been proven to reduce dose to healthy organs-at …
Evaluation of plan quality and treatment efficiency in cranial stereotactic radiosurgery treatment plans with a variable source‐to‐axis distance
Introduction Radiotherapy deliveries with dynamic couch motions that shorten the source‐to‐
axis distance (SAD) on a C‐arm linac have the potential to increase treatment efficiency …
axis distance (SAD) on a C‐arm linac have the potential to increase treatment efficiency …
Dosimetrically motivated beam‐angle optimization for non‐coplanar arc radiotherapy with and without dynamic collimator rotation
J Bertholet, C Zhu, G Guyer, S Mueller… - Medical …, 2024 - Wiley Online Library
Background Non‐coplanar techniques have shown to improve the achievable dose
distribution compared to standard coplanar techniques for multiple treatment sites but …
distribution compared to standard coplanar techniques for multiple treatment sites but …
Non-coplanar trajectory based volumetric modulated arc therapy
J Marshall - 2022 - open.library.ubc.ca
Trajectory volumetric modulated arc therapy (VMAT) is an emerging technique in high
precision radiation therapy. Trajectory VMAT permits modulated radiation treatment delivery …
precision radiation therapy. Trajectory VMAT permits modulated radiation treatment delivery …