[HTML][HTML] Lessons learnt from the recent EURADOS intercomparisons in computational dosimetry

H Rabus, M Zankl, JM Gómez-Ros, C Villagrasa… - Radiation …, 2022 - Elsevier
Abstract Organized by Working Group 6 “Computational Dosimetry” of the European
Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was …

Development and validation of the low‐cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy

V Kopačin, H Brkić, A Ivković… - Journal of applied …, 2024 - Wiley Online Library
Abstract Background Monte Carlo (MC) simulations or measurements in anthropomorphic
phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy …

Significance and feasibility of air kerma length product and air kerma area product comparisons

M Živanović, MV Kortmiš, N Kržanović, M Đaletić… - Radiation …, 2024 - Elsevier
Air kerma length product and air kerma area product are special quantities used in
diagnostic radiology. They are measured using special measurement devices–CT …

A dosimetric comparison between ICRP and ORNL phantoms from exposure to 137Cs contaminated soil

M Živković, MS Beni, KN Peter, H Watabe… - Radiation Physics and …, 2023 - Elsevier
The 137 Cs soil contamination has detrimental effects on human health. The penetration
and distribution of 137 Cs radionuclides at different soil depths were investigated. Two …

Practical overview of the ICRP Publication 145 phantoms for use with MCNP

L Hetrick, J Douglas, D Poudel - Radiation Protection Dosimetry, 2023 - academic.oup.com
This paper provides a practical overview of the mesh-type reference phantoms (MRCPs)
published by the ICRP by providing supplementary guidance on the proper implementation …

[PDF][PDF] Расчет дозы облучения с использованием воксельных фантомов по программе MCU

ЮС Дайченкова, МЮ Никулин… - … атомной науки и …, 2023 - researchgate.net
Аннотация По прецизионной программе MCU, реализующей метод Монте-Карло,
выполнено моделирование расчетных бенчмарк-экспериментов, разработанных …

Direct Monitoring Method to Detect Internal Radioactive Contamination

MY Nadar, L Mishra, IS Singh - … on Radiation Environment, Volume 2: Dose …, 2024 - Springer
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …

EURADOS working group 6, computational dosimetry, a history of promoting good practice via intercomparisons and training

R Tanner, S Agosteo, H Rabus - arXiv preprint arXiv:2208.02568, 2022 - arxiv.org
This paper is the editorial of a special issue of Radiation Measurements on EURADOS
intercomparisons in computational dosimetry. The articles in this special issue cover …

Calculation of X-Ray Dose Loads in the Human Body Using Voxel Phantoms and the MCU Program

MY Nikulin, DS Oleynik, GS Sergeev, DA Shkarovsky - Atomic Energy, 2023 - Springer
A benchmark experiment modeling two typical medical x-ray procedures–chest and
abdominal x-rays–was calculated for the purpose of verifying the MCU computer program for …

[PDF][PDF] Author's version

MY Nikulin, DS Oleynik, GS Sergeev… - Atomic …, 2023 - researchgate.net
Golem Laura Height, m................ 1.76........... 1.63 Weight, kg................ 73............ 60 Number of
tissue voxels........ 1,946,375........ 3,886,020 Total number of voxels......... 7,161,276 …