Solid supports and supported liquid membranes for different liquid phase microextraction and electromembrane extraction configurations. A review
JA Ocaña-González, N Aranda-Merino… - … of Chromatography A, 2023 - Elsevier
Liquid phase microextraction (LPME) and electromembrane microextraction (EME) can be
considered as two of the most popular techniques in sample treatment today. Both …
considered as two of the most popular techniques in sample treatment today. Both …
A review of the application of hollow-fiber liquid-phase microextraction in bioanalytical methods–A systematic approach with focus on forensic toxicology
Over the past three decades, many studies employing hollow-fiber liquid-phase
microextraction (HF-LPME) bioanalytical methods have been published. The basic …
microextraction (HF-LPME) bioanalytical methods have been published. The basic …
Facile and sensitive determination of urinary mandelic acid by combination of metal organic frameworks with microextraction by packed sorbents
In this study, two hybrid metal organic frameworks including MOF-5@ Fe 3 O 4-NH 2 and
MOF-5@ SBA-15 for the first time were synthetized and combined with microextraction by …
MOF-5@ SBA-15 for the first time were synthetized and combined with microextraction by …
Ion‐pair‐based hollow‐fiber liquid‐phase microextraction combined with high‐performance liquid chromatography for the simultaneous determination of urinary …
In the current study, a novel technique for extraction and determination of trans, trans‐
muconic acid, hippuric acid, and mandelic acid was developed by means of ion‐pair‐based …
muconic acid, hippuric acid, and mandelic acid was developed by means of ion‐pair‐based …
Optimization of ion‐pair based hollow fiber liquid phase microextraction combined with HPLC–UV for the determination of methimazole in biological samples and …
H Ebrahimzadeh, AA Asgharinezhad… - Journal of separation …, 2012 - Wiley Online Library
Ion‐pair based hollow fiber liquid phase microextraction (IP‐HFLPME) coupled with high
performance liquid chromatography‐ultraviolet detection was applied for the …
performance liquid chromatography‐ultraviolet detection was applied for the …
Development of Hollow-Fiber Liquid-Phase Microextraction Method for Determination of Urinary trans, trans-Muconic Acid as a Biomarker of Benzene Exposure
For the first time, hollow-fiber liquid-phase microextraction combined with high-performance
liquid chromatography-ultraviolet was used to extract trans, trans-muconic acid, in urine …
liquid chromatography-ultraviolet was used to extract trans, trans-muconic acid, in urine …
Electromembrane extraction using a cylindrical electrode: a new view for the augmentation of extraction efficiency
In the present work, for the first time, a cylindrical electrode that surrounded a hollow fiber
membrane was introduced in electromembrane extraction (EME). The setup introduced …
membrane was introduced in electromembrane extraction (EME). The setup introduced …
Hollow fiber supported liquid membrane extraction combined with HPLC-UV for simultaneous preconcentration and determination of urinary hippuric acid and …
This work describes a new extraction method with hollow-fiber liquid-phase microextraction
based on facilitated pH gradient transport for analyzing hippuric acid and mandelic acid in …
based on facilitated pH gradient transport for analyzing hippuric acid and mandelic acid in …
Simultaneous extraction and determination of trace amounts of olanzapine and fluoxetine from biological fluids: comparison of conventional hollow fiber supported …
In the current work, hollow fiber liquid phase microextraction (HF-LPME) and pulsed
electromembrane extraction (PEME) coupled with high-performance liquid chromatography …
electromembrane extraction (PEME) coupled with high-performance liquid chromatography …
Simultaneous spectrophotometric and chromatographic determination of Ketorolac and Dexamethasone: Overall assessment regarding environmental Impact …
MM Rady, SF Hammad, SF El-Malla - Microchemical Journal, 2024 - Elsevier
Determination of a drug combination that contains a minor component that is also a poorly
UV absorbing analyte represents greet challenges in drug analysis. A fixed-dose ophthalmic …
UV absorbing analyte represents greet challenges in drug analysis. A fixed-dose ophthalmic …