Engineering biocompatible implant surfaces: Part I: Materials and surfaces
S Bauer, P Schmuki, K Von Der Mark, J Park - Progress in Materials …, 2013 - Elsevier
During recent decades vast and continuously increasing numbers of biomedical implants
have been introduced for continuous use in the human body. Since the early cemented hip …
have been introduced for continuous use in the human body. Since the early cemented hip …
Calcium phosphate coatings for bio-implant applications: Materials, performance factors, and methodologies
SR Paital, NB Dahotre - Materials Science and Engineering: R: Reports, 2009 - Elsevier
With an ageing population, war, and sports related injuries there is an ever-expanding
requirement for hard tissue replacement such as bone. Engineered artificial scaffold …
requirement for hard tissue replacement such as bone. Engineered artificial scaffold …
Volumetric wear assessment of retrieved metal-on-metal hip prostheses and the impact of measurement uncertainty
In hip replacement the use of hard bearing materials, which have been shown to have lower
wear rates than traditional metal-UHMWPE couples, has been encouraged in an effort to …
wear rates than traditional metal-UHMWPE couples, has been encouraged in an effort to …
Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
Recent advancements in hip arthroplasty have allowed the operation to boast excellent
results and high survivorship. However, failures do still occur and a major cause is …
results and high survivorship. However, failures do still occur and a major cause is …
New challenges in tribology: wear assessment using 3D optical scanners
MC Valigi, S Logozzo, S Affatato - Materials, 2017 - mdpi.com
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the
tribological phenomena that involve freeform mechanical components or medical …
tribological phenomena that involve freeform mechanical components or medical …
Traceable volume measurements using coordinate measuring systems
S Carmignato, E Savio - CIRP annals, 2011 - Elsevier
Accurate quantification of volume is important in many different applications, including
calibration of containers for fluids, wear evaluation, and inspection of cavities and medical …
calibration of containers for fluids, wear evaluation, and inspection of cavities and medical …
Uncertainty evaluation of volumetric wear assessment from coordinate measurements of ceramic hip joint prostheses
S Carmignato, M Spinelli, S Affatato, E Savio - Wear, 2011 - Elsevier
Replaced hip joints are normally expected to last 15–20 years. However, although the
procedure is nowadays successfully performed, up to 10% of procedures carried out are …
procedure is nowadays successfully performed, up to 10% of procedures carried out are …
The role of tribology and metrology in the latest development of bio-materials
Total joint replacement is one of the most common elective surgical procedures performed
worldwide, with an estimate of 1.5 million operations performed annually. Currently joint …
worldwide, with an estimate of 1.5 million operations performed annually. Currently joint …
Knee wear assessment: 3D scanners used as a consolidated procedure
S Affatato, MC Valigi, S Logozzo - Materials, 2020 - mdpi.com
It is well known that wear occurring in polyethylene menisci is a significant clinical problem.
At this regard, wear tests on biomaterials medical devices are performed in order to assess …
At this regard, wear tests on biomaterials medical devices are performed in order to assess …
Wear distribution detection of knee joint prostheses by means of 3D optical scanners
S Affatato, MC Valigi, S Logozzo - Materials, 2017 - mdpi.com
The objective of this study was to examine total knee polyethylene inserts from in vitro
simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear …
simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear …