Rapid brain MRI acquisition techniques at ultra‐high fields
Ultra‐high‐field MRI provides large increases in signal‐to‐noise ratio (SNR) as well as
enhancement of several contrast mechanisms in both structural and functional imaging …
enhancement of several contrast mechanisms in both structural and functional imaging …
Real‐time distortion correction of spiral and echo planar images using the gradient system impulse response function
AE Campbell‐Washburn, H Xue… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose MRI‐guided interventions demand high frame rate imaging, making fast imaging
techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study …
techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study …
Image reconstruction using a gradient impulse response model for trajectory prediction
Purpose Gradient imperfections remain a challenge in MRI, especially for sequences relying
on long imaging readouts. This work aims to explore image reconstruction based on k …
on long imaging readouts. This work aims to explore image reconstruction based on k …
Single‐shot spiral imaging enabled by an expanded encoding model: D emonstration in diffusion MRI
BJ Wilm, C Barmet, S Gross, L Kasper… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose The purpose of this work was to improve the quality of single‐shot spiral MRI and
demonstrate its application for diffusion‐weighted imaging. Methods Image formation is …
demonstrate its application for diffusion‐weighted imaging. Methods Image formation is …
Real‐time motion correction using gradient tones and head‐mounted NMR field probes
M Haeberlin, L Kasper, C Barmet… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose Sinusoidal gradient oscillations in the kilohertz range are proposed for position
tracking of NMR probes and prospective motion correction for arbitrary imaging sequences …
tracking of NMR probes and prospective motion correction for arbitrary imaging sequences …
[HTML][HTML] Analysis of temperature dependence of background phase errors in phase-contrast cardiovascular magnetic resonance
J Busch, SJ Vannesjo, C Barmet… - Journal of …, 2014 - Elsevier
Background The accuracy of phase-contrast cardiovascular magnetic resonance (PC-CMR)
can be compromised by background phase errors. It is the objective of the present work to …
can be compromised by background phase errors. It is the objective of the present work to …
Analysis and correction of field fluctuations in fMRI data using field monitoring
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In
standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and …
standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and …
[HTML][HTML] Advances in spiral fMRI: A high-resolution study with single-shot acquisition
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging,
in particular due to its enhanced average k-space speed and thus high acquisition …
in particular due to its enhanced average k-space speed and thus high acquisition …
Single‐shot spiral imaging at 7 T
M Engel, L Kasper, C Barmet, T Schmid… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose The purpose of this work is to explore the feasibility and performance of single‐shot
spiral MRI at 7 T, using an expanded signal model for reconstruction. Methods Gradient …
spiral MRI at 7 T, using an expanded signal model for reconstruction. Methods Gradient …
Rapid measurement and correction of spatiotemporal B0 field changes using FID navigators and a multi‐channel reference image
Purpose To measure spatiotemporal B0 field changes in real time using FID navigators
(FIDnavs) and to demonstrate the efficacy of retrospectively correcting high‐resolution …
(FIDnavs) and to demonstrate the efficacy of retrospectively correcting high‐resolution …