Rapid brain MRI acquisition techniques at ultra‐high fields

K Setsompop, DA Feinberg, JR Polimeni - NMR in Biomedicine, 2016 - Wiley Online Library
Ultra‐high‐field MRI provides large increases in signal‐to‐noise ratio (SNR) as well as
enhancement of several contrast mechanisms in both structural and functional imaging …

Real‐time distortion correction of spiral and echo planar images using the gradient system impulse response function

AE Campbell‐Washburn, H Xue… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose MRI‐guided interventions demand high frame rate imaging, making fast imaging
techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study …

Image reconstruction using a gradient impulse response model for trajectory prediction

SJ Vannesjo, NN Graedel, L Kasper… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose Gradient imperfections remain a challenge in MRI, especially for sequences relying
on long imaging readouts. This work aims to explore image reconstruction based on k …

Single‐shot spiral imaging enabled by an expanded encoding model: D emonstration in diffusion MRI

BJ Wilm, C Barmet, S Gross, L Kasper… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose The purpose of this work was to improve the quality of single‐shot spiral MRI and
demonstrate its application for diffusion‐weighted imaging. Methods Image formation is …

Real‐time motion correction using gradient tones and head‐mounted NMR field probes

M Haeberlin, L Kasper, C Barmet… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose Sinusoidal gradient oscillations in the kilohertz range are proposed for position
tracking of NMR probes and prospective motion correction for arbitrary imaging sequences …

[HTML][HTML] Analysis of temperature dependence of background phase errors in phase-contrast cardiovascular magnetic resonance

J Busch, SJ Vannesjo, C Barmet… - Journal of …, 2014 - Elsevier
Background The accuracy of phase-contrast cardiovascular magnetic resonance (PC-CMR)
can be compromised by background phase errors. It is the objective of the present work to …

Analysis and correction of field fluctuations in fMRI data using field monitoring

S Bollmann, L Kasper, SJ Vannesjo, AO Diaconescu… - Neuroimage, 2017 - Elsevier
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In
standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and …

[HTML][HTML] Advances in spiral fMRI: A high-resolution study with single-shot acquisition

L Kasper, M Engel, J Heinzle, M Mueller-Schrader… - NeuroImage, 2022 - Elsevier
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging,
in particular due to its enhanced average k-space speed and thus high acquisition …

Single‐shot spiral imaging at 7 T

M Engel, L Kasper, C Barmet, T Schmid… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose The purpose of this work is to explore the feasibility and performance of single‐shot
spiral MRI at 7 T, using an expanded signal model for reconstruction. Methods Gradient …

Rapid measurement and correction of spatiotemporal B0 field changes using FID navigators and a multi‐channel reference image

TE Wallace, O Afacan, T Kober… - Magnetic resonance in …, 2020 - Wiley Online Library
Purpose To measure spatiotemporal B0 field changes in real time using FID navigators
(FIDnavs) and to demonstrate the efficacy of retrospectively correcting high‐resolution …