Innervation zone locations in 43 superficial muscles: toward a standardization of electrode positioning

M Beretta Piccoli, A Rainoldi, C Heitz… - Muscle & …, 2014 - Wiley Online Library
Introduction: We describe the innervation zone (IZ) location in 43 muscles to provide
information for appropriate positioning of bipolar electrodes for clinical and research …

Flexible inkjet‐printed multielectrode arrays for neuromuscular cartography

T Roberts, JB De Graaf, C Nicol, T Hervé… - Advanced …, 2016 - Wiley Online Library
Flexible Poly (3, 4‐ethylenedioxythiophene)‐poly (styrenesulfonate)(PEDOT: PSS)
conductive‐polymer multielectrode arrays (MEAs) are fabricated without etching or …

Enhanced dynamic EMG-force estimation through calibration and PCI modeling

J Hashemi, E Morin, P Mousavi… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
To accurately estimate muscle forces using electromyogram (EMG) signals, precise EMG
amplitude estimation, and a modeling scheme capable of coping with the nonlinearities and …

EMG-torque relation in chronic stroke: A novel EMG complexity representation with a linear electrode array

X Zhang, D Wang, Z Yu, X Chen, S Li… - IEEE Journal of …, 2016 - ieeexplore.ieee.org
This study examines the electromyogram (EMG)-torque relation for chronic stroke survivors
using a novel EMG complexity representation. Ten stroke subjects performed a series of …

Deep Learning Approach in Hand Motion Recognition Using Electromyography Signal: A Review

T Triwiyanto, T Rahmawati, A Pudji, MR Mak'ruf… - Proceedings of the 2nd …, 2022 - Springer
Electromyography (EMG) signals have very high complexity and random characteristics.
EMG signals are widely used in the process of controlling rehabilitation engineering …

Re-evaluation of EMG-torque relation in chronic stroke using linear electrode array EMG recordings

M Bhadane, J Liu, WZ Rymer, P Zhou, S Li - Scientific reports, 2016 - nature.com
The objective was to re-evaluate the controversial reports of EMG-torque relation between
impaired and non-impaired sides using linear electrode array EMG recordings. Ten subjects …

Relationship between isometric muscle force and fractal dimension of surface electromyogram

M Beretta-Piccoli, G Boccia, T Ponti… - BioMed research …, 2018 - Wiley Online Library
The relationship between fractal dimension of the surface electromyogram (sEMG) and the
intensity of muscle contraction is still controversial in simulated and experimental conditions …

Surface EMG force modeling with joint angle based calibration

J Hashemi, E Morin, P Mousavi… - … of Electromyography and …, 2013 - Elsevier
In this paper, a calibration method to compensate for changes in SEMG amplitude with joint
angle is introduced. Calibration factors were derived from constant amplitude surface …

EMG-force relationship during static contraction: Effects on sensor placement locations on biceps brachii muscle

NU Ahamed, K Sundaraj, M Alqahtani… - … and Health Care, 2014 - content.iospress.com
Background: The relationship between surface electromyography (EMG) and force have
been the subject of ongoing investigations and remain a subject of controversy. Even under …

Deep learning approach to improve the recognition of hand gesture with multi force variation using electromyography signal from amputees

T Triwiyanto, IPA Pawana, W Caesarendra - Medical Engineering & Physics, 2024 - Elsevier
Variations in muscular contraction are known to significantly impact the quality of the
generated EMG signal and the output decision of a proposed classifier. This is an issue …