Structural robustness and timber buildings–a review
Timber buildings are increasing in their dimensions. Structural robustness is imperative for
all buildings and specifically important for tall buildings. Lives can be saved if …
all buildings and specifically important for tall buildings. Lives can be saved if …
Steel-concrete frames under the column loss scenario: An experimental study
R Zandonini, N Baldassino, F Freddi… - Journal of Constructional …, 2019 - Elsevier
Accidental events, such as impact loading or explosions, are rare events with a very low
probability of occurrence. However, their effects often lead to very high human losses and …
probability of occurrence. However, their effects often lead to very high human losses and …
Modelling of connection behaviour for progressive collapse analysis
PM Stylianidis, DA Nethercot - Journal of Constructional Steel Research, 2015 - Elsevier
The structural robustness of frame structures depends to a considerable extent on the ability
of the connections between the main structural elements to transmit the sorts of loading …
of the connections between the main structural elements to transmit the sorts of loading …
Static and dynamic tests on steel joints equipped with novel structural details for progressive collapse mitigation
G Bregoli, G Vasdravellis, TL Karavasilis… - Engineering …, 2021 - Elsevier
This paper presents static and dynamic tests on nominally-pinned steel joints equipped with
novel structural details for progressive collapse mitigation. The proposed structural details …
novel structural details for progressive collapse mitigation. The proposed structural details …
Experimental test simulating a column loss in a composite frame
JF Demonceau, JP Jaspart - Advanced Steel Construction, 2010 - orbi.uliege.be
Recent events such as natural catastrophes or terrorism attacks have highlighted the
necessity to ensure the structural integrity of buildings under exceptional events. According …
necessity to ensure the structural integrity of buildings under exceptional events. According …
Pilot experimental and numerical studies on a novel retrofit scheme for steel joints against progressive collapse
B Ghorbanzadeh, G Bregoli, G Vasdravellis… - Engineering …, 2019 - Elsevier
Current design standards require that beam-column joints should withstand a minimum tie
force in the case of an extreme loading event resulting in the loss of one or more columns to …
force in the case of an extreme loading event resulting in the loss of one or more columns to …
[PDF][PDF] Experimental tests of steel unstiffened double side joints with flush and extended end plate
K Aleksander, D Kukla - Archives of Civil Engineering, 2019 - archive.sciendo.com
Experimental tests of steel unstiffened double side bolted end-plate joints have been
presented. The main aim of the conducted tests was to check the behavior of joints in an …
presented. The main aim of the conducted tests was to check the behavior of joints in an …
Improving the structural robustness of multi-story steel-frame buildings
Although there are numerous hazards that could trigger the progressive collapse of a
building, there are limited provisions in related codes regarding the design of structures to …
building, there are limited provisions in related codes regarding the design of structures to …
Robustness assessment of frame structures using simplified beam and grillage models
PM Stylianidis, DA Nethercot, BA Izzuddin… - Engineering …, 2016 - Elsevier
Simplified analysis methods derived in previous studies are employed for studying the
progressive collapse behaviour of steel and composite buildings. A regular frame building is …
progressive collapse behaviour of steel and composite buildings. A regular frame building is …
Robustness of beam-to-column end-plate moment connections with stainless steel bolts subjected to high rates of loading
G Culache, MP Byfield, NS Ferguson… - Journal of Structural …, 2017 - ascelibrary.org
This paper presents an experimental investigation into end-plate beam column connections
for buildings. The work demonstrates that a fourfold increase in the energy absorbed to …
for buildings. The work demonstrates that a fourfold increase in the energy absorbed to …