Mock circulatory loop applications for testing cardiovascular assist devices and in vitro studies

KW Xu, Q Gao, M Wan, K Zhang - Frontiers in Physiology, 2023 - frontiersin.org
The mock circulatory loop (MCL) is an in vitro experimental system that can provide
continuous pulsatile flows and simulate different physiological or pathological parameters of …

Left ventricular assist device as destination therapy: a state of the science and art of long-term mechanical circulatory support

TC Hanff, EY Birati - Current Heart Failure Reports, 2019 - Springer
Abstract Purpose of Review The purpose of this review is to synthesize and summarize
recent developments in the care of patients with end-stage heart failure being managed with …

Dynamic load modulation predicts right heart tolerance of left ventricular cardiovascular assist in a porcine model of cardiogenic shock

KK Lamberti, SP Keller, ER Edelman - Science translational medicine, 2024 - science.org
Ventricular assist devices (VADs) offer mechanical support for patients with cardiogenic
shock by unloading the impaired ventricle and increasing cardiac outflow and subsequent …

Two-year follow up of the LATERAL clinical trial: a focus on adverse events

GM Wieselthaler, L Klein, AW Cheung… - Circulation: Heart …, 2021 - Am Heart Assoc
Background: The LATERAL trial validated the safety and efficacy of the thoracotomy
approach for implantation of the HeartWare HVAD System, leading to Food and Drug …

Percutaneous venopulmonary artery extracorporeal membrane oxygenation for right heart failure after left ventricular assist device insertion

Y Joshi, MC Bories, N Aissaoui… - Interactive …, 2021 - academic.oup.com
OBJECTIVES Right ventricular failure after left ventricular assist device (LVAD) insertion is
associated with significant mortality and morbidity. Mechanical support options include right …

Arterial compliance and continuous-flow left ventricular assist device pump function

A Adji, S Shehab, P Jain, D Robson, P Jansz… - ASAIO …, 2022 - journals.lww.com
Durable continuous-flow left ventricular assist devices (cfLVADs) demonstrate superior
survival, cardiac functional status, and overall quality of life compared to medical therapy …

Valvular regurgitation in a biventricular mock circulatory loop

S Shehab, SM Allida, PJ Newton, D Robson… - Asaio …, 2019 - journals.lww.com
Aortic regurgitation (AR), mitral regurgitation (MR), and tricuspid regurgitation (TR) after
continuous-flow left ventricular assist device (LVAD) are common and may increase with …

Effect of RVAD Cannulation Length on Right Ventricular Thrombosis Risk: An In Silico Investigation

KY Thum, S Liao, M Šeman, M Khamooshi… - Annals of Biomedical …, 2024 - Springer
Left ventricular assist devices (LVADs) have been used off-label as long-term support of the
right heart due to the lack of a clinically approved durable right VAD (RVAD). Whilst various …

Patient-specific, echocardiography compatible flow loop model of aortic valve regurgitation in the setting of a mechanical assist device

M Kassi, S Filippini, E Avenatti, S Xu… - Frontiers in …, 2023 - frontiersin.org
Background Aortic regurgitation (AR) occurs commonly in patients with continuous-flow left
ventricular assist devices (LVAD). No gold standard is available to assess AR severity in this …

Pulsatile conduit pressure gradients in the HeartWare HVAD

P Jain, S Shehab, M Stevens, P Macdonald… - ASAIO …, 2019 - journals.lww.com
We evaluated mean, peak, and instantaneous pressure gradients across the outflow conduit
in a pulsatile mock circulation loop which incorporated Heartware HVADs for left ventricular …