Silicon technologies for the CLIC vertex detector
S Spannagel - Journal of Instrumentation, 2017 - iopscience.iop.org
CLIC is a proposed linear e+ e-collider designed to provide particle collisions at center-of-
mass energies of up to 3 TeV. Precise measurements of the properties of the top quark and …
mass energies of up to 3 TeV. Precise measurements of the properties of the top quark and …
Intermetallic compound layer formation in indium-based micro-bump array fabrication technology for IR detectors
P Kozłowski, A Jasik, A Łaszcz, K Czuba… - Opto-Electronics …, 2024 - repo.pw.edu.pl
This work reports on the investigation of homogeneity of the inside of indium micro-
bumps/columns placed on Ti/Pt/Au under bump metallisation. This is very important for …
bumps/columns placed on Ti/Pt/Au under bump metallisation. This is very important for …
Silicon pixel-detector R&D for CLIC
A Nürnberg - Journal of Instrumentation, 2016 - iopscience.iop.org
The physics aims at the future CLIC high-energy linear e+ e-collider set very high precision
requirements on the performance of the vertex and tracking detectors. Moreover, these …
requirements on the performance of the vertex and tracking detectors. Moreover, these …
Silicon pixel R&D for CLIC
M Munker - Journal of Instrumentation, 2017 - iopscience.iop.org
Challenging detector requirements are imposed by the physics goals at the future multi-TeV
e+ e− Compact Linear Collider (CLIC). A single point resolution of 3 μm for the vertex …
e+ e− Compact Linear Collider (CLIC). A single point resolution of 3 μm for the vertex …
Capacitive Micromachined Ultrasonic Transducer Packaging for Forward-looking Ultrasonic Endoscope using Low Temperature Co-fired Ceramic Side Via
This paper reports part of a novel packaging method for a capacitive micromachined
ultrasonic transducer (CMUT) based ultrasonic endoscope using low temperature co-fired …
ultrasonic transducer (CMUT) based ultrasonic endoscope using low temperature co-fired …
Status of silicon detector R&D; at CLIC
M Munker - 2019 - cds.cern.ch
Abstract The Compact Linear Collider CLIC, a multi-TeV linear electron-positron collider,
aims at precision measurements of the Standard Model, as well as direct and indirect …
aims at precision measurements of the Standard Model, as well as direct and indirect …
Silicon pixel R&D; for the CLIC detector
D Hynds - 2016 - cds.cern.ch
The physics aims at the future CLIC high-energy linear $ e^{+} e^{−} $ collider set very high
precision requirements on the performance of the vertex and tracking detectors. Moreover …
precision requirements on the performance of the vertex and tracking detectors. Moreover …
Flip chip assembly for cryogenics and flexible substrates
A Tomada, J Segal, J Hasi, C Kenney… - 2015 IEEE Nuclear …, 2015 - ieeexplore.ieee.org
Many elementary-particle and nuclear physics experiments are performed at cryogenic
temperatures. As channels counts and sensor densities increase there is a growing need for …
temperatures. As channels counts and sensor densities increase there is a growing need for …
Vertex and Tracker Research and Development for CLIC
RM Munker - CERN Proceedings, 2017 - e-publishing.cern.ch
Challenging detector requirements are imposed by the physics goals at the future multi-TeV
e+ e− Compact Linear Collider (CLIC). A single point resolution of 3 μm for the vertex …
e+ e− Compact Linear Collider (CLIC). A single point resolution of 3 μm for the vertex …
[PDF][PDF] Silicon pixel-detector R&D for CLIC
S Spannagel, Z Deng, L He, F Liu - 2016 - s3.cern.ch
The Compact Linear Collider (CLIC) is an e+ e-linear collider proposed for the post HL-LHC
phase [1, 2] providing collision with a center-of-mass energy of up to 3 TeV [3]. Its physics …
phase [1, 2] providing collision with a center-of-mass energy of up to 3 TeV [3]. Its physics …