Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Monte Carlo treatment planning for photon and electron beams

N Reynaert, SC Van der Marck, DR Schaart… - Radiation Physics and …, 2007 - Elsevier
During the last few decades, accuracy in photon and electron radiotherapy has increased
substantially. This is partly due to enhanced linear accelerator technology, providing more …

Stereotactic body radiation therapy: the report of AAPM Task Group 101

SH Benedict, KM Yenice, D Followill, JM Galvin… - Medical …, 2010 - Wiley Online Library
Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and
therapists in order to outline the best practice guidelines for the external‐beam radiation …

Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions

IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …

Testing of the analytical anisotropic algorithm for photon dose calculation

A Van Esch, L Tillikainen, J Pyykkonen… - Medical …, 2006 - Wiley Online Library
The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical
Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for …

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations

B Vanderstraeten, N Reynaert, L Paelinck… - Medical …, 2006 - Wiley Online Library
The accuracy of dose computation within the lungs depends strongly on the performance of
the calculation algorithm in regions of electronic disequilibrium that arise near tissue …

Assessing the effect of electron density in photon dose calculations

J Seco, PM Evans - Medical physics, 2006 - Wiley Online Library
Photon dose calculation algorithms (such as the pencil beam and collapsed cone, CC)
model the attenuation of a primary photon beam in media other than water, by using …

Comparison of inhomogeneity correction algorithms in small photon fields

AO Jones, IJ Das - Medical physics, 2005 - Wiley Online Library
Algorithms such as convolution superposition, Batho, and equivalent pathlength which were
originally developed and validated for conventional treatments under conditions of …

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear …

E Sterpin, M Tomsej, B De Smedt, N Reynaert… - Medical …, 2007 - Wiley Online Library
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition
algorithm proposed by Varian for photon dose calculations. The configuration of AAA …

Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for photon fields smaller than produced by Cyberknife

EE Wilcox, GM Daskalov - Medical physics, 2008 - Wiley Online Library
For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic
disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the …