Two-dimensional Mo3-TiS2 monolayer hosting high moisture resistance and abundant surface-chemisorbed oxygen for effective detection of SF6 decomposition …

L Huang, T Li, W Zeng, Q Zhou - Applied Surface Science, 2024 - Elsevier
Monitoring the SF 6 decomposition gas (DPA) by gas sensors can be used to predict the
operating status of power equipment, and the sensitivity performance of gas sensors is …

Optimal reconfiguration-based dynamic tariff for congestion management and line loss reduction in distribution networks

S Huang, Q Wu, L Cheng, Z Liu - IEEE Transactions on Smart …, 2015 - ieeexplore.ieee.org
This paper presents an optimal reconfiguration-based dynamic tariff (DT) method for
congestion management and line loss reduction in distribution networks with high …

A data mining transmission switching heuristic for post-contingency AC power flow violation reduction in real-world, large-scale systems

WE Brown, E Moreno-Centeno - Computers & Operations Research, 2023 - Elsevier
Transmission switching has proven to be a highly useful post-contingency recovery
technique by allowing power system operators increased levels of control through …

A linear capacitive sensor for ppm moisture measurement in SF₆ gas-insulated switchgear

ZH Zargar, KJ Akram, GR Biswal… - IEEE transactions on …, 2020 - ieeexplore.ieee.org
Moisture measurement and control is very essential for gas-insulated switchgear (GIS). For
safe and reliable operation, the moisture inside GIS needs to be kept within the prescribed …

Online condition assessment of interruption chamber of gas circuit breakers using arc voltage measurement

A Bagherpoor, S Rahimi-Pordanjani… - … on Power Delivery, 2016 - ieeexplore.ieee.org
As a key element of a power system, a circuit breaker (CB) requires regular maintenance.
Intelligent online condition assessment is increasingly becoming a requirement for key items …

Power-system protection device with IoT-based support for integration in smart environments

OM Machidon, C Stanca, P Ogrutan, C Gerigan… - PLoS One, 2018 - journals.plos.org
This paper proposes a power-system protection device designed to be integrated in smart
environments based on Internet-of-Things technologies. The proposed system enhances …

Hardware-in-the-loop simulation applied to protection devices testing

O Crăciun, A Florescu, I Munteanu, AI Bratcu… - International Journal of …, 2014 - Elsevier
Circuit breakers are ubiquitous elements used for ensuring safe operation of low-voltage
power systems. Nowadays the loads supplied by the power systems migrate towards …

Temperature-Robust All-Fiber Demodulation of Optical Current Sensor Using Long-Period Grating on Birefringent Photonic Crystal Fiber

G Bae, J Kim, S Choi, M Bae, YW Lee - IEEE Sensors Journal, 2024 - ieeexplore.ieee.org
By incorporating a long-period fiber grating (LPFG) inscribed on birefringent photonic crystal
fiber (BPCF) with a CO2 laser as a polarization analyzer, we demonstrate temperature …

An internet-of-things design approach to real-time monitoring and protection of a residential power system

MO Onibonoje, NI Nwulu… - 2019 IEEE 7th …, 2019 - ieeexplore.ieee.org
The need for fault detection and isolation of power supply from appliances is a vital
component of safety in homes and residential facilities. There is a growing trend and …

Application of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level

J Liu, X Hao, X Wang, Y Chen… - Journal of Modern …, 2018 - ieeexplore.ieee.org
Short-circuit fault current suppression is a very important issue in modern large-
interconnected power networks. Conventional short-circuit current limiters, such as …