Role of electrode placement as a contributor to variability in cochlear implant outcomes

CC Finley, TA Holden, LK Holden… - Otology & …, 2008 - journals.lww.com
Suboptimal cochlear implant (CI) electrode array placement may reduce presentation of
coded information to the central nervous system and, consequently, limit speech recognition …

Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode …

E Boyer, A Karkas, A Attye, V Lefournier… - Otology & …, 2015 - journals.lww.com
Scalar Localization by Cone-Beam Computed Tomography of Coch... : Otology &
Neurotology Scalar Localization by Cone-Beam Computed Tomography of Cochlear …

Accuracy of computed tomography detection of superior canal dehiscence

SM Sequeira, BR Whiting, JS Shimony… - Otology & …, 2011 - journals.lww.com
Background CT is an integral component of the diagnosis of SSCD. The prevalence of
dehiscence as measured on computed tomographic scan is approximately eightfold higher …

[HTML][HTML] Reliability of cone beam computed tomography in scalar localization of the electrode array: a radio histological study

M Marx, F Risi, B Escudé, I Durmo, C James… - European Archives of …, 2014 - Springer
Postoperative imaging plays a growing role in clinical studies concerning prognostic factors
in cochlear implantation. Indeed, intracochlear position of the cochlear implant has recently …

Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis

J Teymouri, TE Hullar, TA Holden… - Otology & …, 2011 - journals.lww.com
Objective: To determine the efficacy of clinical computed tomographic (CT) imaging to verify
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …

Cochlear duct length–one size fits all?

JF Thong, D Low, A Tham, C Liew, TY Tan… - American journal of …, 2017 - Elsevier
Objective Recent studies demonstrated the utility of high-resolution computed tomography
(HRCT) scans in measuring basal cochlear length and cochlear insertion depths. These …

High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants

MS Pearl, A Roy, CJ Limb - American Journal of …, 2014 - Am Soc Neuroradiology
Radiologic assessment of cochlear implants can be limited because of metallic streak
artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 …

[HTML][HTML] 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study

D De Seta, P Mancini, FY Russo, R Torres… - Acta …, 2016 - ncbi.nlm.nih.gov
SUMMARY A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and
14 fresh temporal bones that underwent cochlear implantation with straight flexible …

Design of a tool integrating force sensing with automated insertion in cochlear implantation

D Schurzig, RF Labadie, A Hussong… - IEEE/ASME …, 2011 - ieeexplore.ieee.org
The quality of hearing restored to a deaf patient by a cochlear implant in hearing
preservation cochlear implant surgery (and possibly also in routine cochlear implant …

[HTML][HTML] 64 MDCT in multiple trauma patients: imaging manifestations and clinical implications of active extravasation

SW Anderson, BC Lucey, JT Rhea, JA Soto - Emergency radiology, 2007 - Springer
The finding of active hemorrhage on computed tomography (CT) in trauma patients has
been shown to have significant clinical implications and has been incorporated into …