[HTML][HTML] Optimization and Experiment of Supercritical Helium Flow in Cryopump

Q Wang, B Li, H Hong, F Wang, Y Zhu, W Yi… - Nuclear Engineering …, 2024 - Elsevier
Large built-in cryopumps are widely used in nuclear fusion devices, the cryopumps studied
in the paper are mainly used to provide a vacuum environment for beam generation and …

Characteristics of the positive ion source at reduced gas feed

SK Sharma, P Bharathi, V Prahlad, PJ Patel… - Review of Scientific …, 2014 - pubs.aip.org
The neutral beam injector of steady state superconducting tokamak (SST1-NBI) at IPR is
designed for injecting upto 1.7 MW of neutral beam (Hº, 30–55 keV) power to the tokamak …

Indian Test Facility (INTF)-a status update

A Chakraborty, U Baruah… - 2015 IEEE 26th …, 2015 - ieeexplore.ieee.org
The Indian Test Facility (INTF) for Neutral Beams is designed with the objective to not only
test the performance of an ion source but also to characterize the transmission of the Neutral …

Operational characteristics of NBI cryo-condensation pumps

B Pandya, AK Sahu, V Prahlad, SK Sharma, LK Bansal… - 2017 - indianjournals.com
Neutral Beam Injector (NBI) is used as an effective tool for heating plasma in magnetic
confinement devices, namely the Tokamak. Cryo-condensation pump is an important …

A prototype experiment on cryocooler based cryopump

M Patel, AK Chakraborty, M Bandyopadhyay, C Rotti… - 2018 - indianjournals.com
To characterize ITER Diagnostic Neutral Beam (DNB) in Indian test facility (INTF),∼ 106 l/s
installed pumping speed is required to ensure low re-ionization losses and stripping losses …

Integration of cryopump instrumentation for SST-1 NBI

LK Bansal, PJ Patel, V Prahlad, K Qureshi, VB Patel… - 2015 - indianjournals.com
A positive ion neutral injector (PINI) capable in delivering 5MW (55kV, 90A) ion beam power
is being operated for SST-1 neutral beam injection (NBI). The production and neutralization …

Hydraulic and thermal analysis for cryodistribution lines of cryopumps for NBI system of SST-1

B Pandya, A Sahu, B Choksi, N Contractor, S Parmar - 2015 - indianjournals.com
Cryo pumps had been developed for the long duration continuous pumping (∼ 4000sec)
with pumping speed of 2× 105I/sec of hydrogen for the Steady state Superconducting …

[引用][C] Indian Test Facility (INTF)–a Status Update

G Bansal, A Gahlaut, V Mahesh, H Mistry, R Pandey

[引用][C] DESIGN AND OPTIMIZATION OF VACUUM BARRIER FOR CRYOGENIC TRANSFER LINE

GS Patel, BP Pandya, AN Shukla, V Prahlad