Drift estimates in frame buildings subjected to near-fault ground motions

S Akkar, U Yazgan, P Gülkan - Journal of Structural Engineering, 2005 - ascelibrary.org
A simple procedure to estimate the local displacement demands in regular frame-type
structures that respond in elastic limits is described. Given the spectral displacement and …

A Review of Simplified Numerical Beam-like Models of Multi-Storey Framed Buildings

A Greco, S Caddemi, I Caliò, I Fiore - Buildings, 2022 - mdpi.com
Modern computational techniques have greatly influenced the numerical analyses of
structures, not only in terms of calculation speed, but also in terms of procedural approach …

Generalized interstory drift spectrum

E Miranda, SD Akkar - Journal of structural engineering, 2006 - ascelibrary.org
The recently developed drift spectrum is extended to buildings that do not deform laterally
like pure shear beams. Similarly to Iwan's drift spectrum, the proposed generalized interstory …

Dynamic behavior of adjacent buildings connected by linear viscous/viscoelastic dampers

E Tubaldi - Structural Control and Health Monitoring, 2015 - Wiley Online Library
This paper analyzes the properties of the dynamic behavior of two adjacent buildings of
different height connected by viscous/viscoelastic dampers located at the top of the shortest …

Interstory drift ratio of building structures subjected to near-fault ground motions based on generalized drift spectral analysis

D Yang, J Pan, G Li - Soil Dynamics and Earthquake Engineering, 2010 - Elsevier
This paper focuses on the interstory drift ratio (IDR) demands of building structures
subjected to near-fault ground motions having different impulsive characteristics based on …

Nonlinear interstory drift contours for idealized forward directivity pulses using “modified fish-bone” models

AR Khaloo, H Khosravi… - Advances in Structural …, 2015 - journals.sagepub.com
Four 5-, 10-, 20-and 30-story moment frames, representing low-, mid-, and two high-rise
structures, were subjected to a great number of idealized directivity pulses. The amplitudes …

A data-driven building's seismic response estimation method using a deep convolutional neural network

J Li, Z He, X Zhao - IEEE Access, 2021 - ieeexplore.ieee.org
As a refined finite element model takes much effort to build and tune to simulate the building
structure's response under seismic effects, many rapid estimation methods were proposed to …

Simplified assessment of maximum interstory drift for RC buildings with irregular infills distribution along the height

M Gaetani d'Aragona, M Polese, E Cosenza… - Bulletin of Earthquake …, 2019 - Springer
This paper investigates on the effect of story lateral stiffness variation on the maximum
elastic interstory drift ratio (IDR max) for existing reinforced concrete (RC) buildings. Several …

Influence of a subway station on the inter-story drift ratio of adjacent surface structures

J Guo, J Chen, A Bobet - Tunnelling and underground space technology, 2013 - Elsevier
The existence of a subway station changes the original site conditions, local ground motions
and, as a consequence, the seismic response of adjacent buildings. The paper investigates …

Can simple pulses adequately represent near-fault ground motions?

R Rupakhety, R Sigbjörnsson - Journal of earthquake engineering, 2011 - Taylor & Francis
This article investigates the importance of higher modes in the elastic response of tall
buildings subjected to near-fault ground motions. Building structures modeled as generic …