Ultrafast cardiac ultrasound imaging: technical principles, applications, and clinical benefits

M Cikes, L Tong, GR Sutherland, J D'hooge - JACC: Cardiovascular …, 2014 - jacc.org
Several recent technical advances in cardiac ultrasound allow data to be acquired at a very
high frame rate. Retrospective gating, plane/diverging wave imaging, and multiline transmit …

Practical guide to ultrasound beam forming: Beam pattern and image reconstruction analysis

L Demi - Applied Sciences, 2018 - mdpi.com
Starting from key ultrasound imaging features such as spatial and temporal resolution,
contrast, penetration depth, array aperture, and field-of-view (FOV) size, the reader will be …

Ultrasound open platforms for next-generation imaging technique development

E Boni, CH Alfred, S Freear, JA Jensen… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Open platform (OP) ultrasound systems are aimed primarily at the research community. They
have been at the forefront of the development of synthetic aperture, plane wave, shear wave …

Ultrasound vector flow imaging—Part II: Parallel systems

JA Jensen, SI Nikolov, CH Alfred… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
This paper gives a review of the current state-of-the-art in ultrasound parallel acquisition
systems for flow imaging using spherical and plane waves emissions. The imaging methods …

A pipeline for the generation of realistic 3D synthetic echocardiographic sequences: Methodology and open-access database

M Alessandrini, M De Craene… - IEEE transactions on …, 2015 - ieeexplore.ieee.org
Quantification of cardiac deformation and strain with 3D ultrasound takes considerable
research efforts. Nevertheless, a widespread use of these techniques in clinical practice is …

High frame-rate, high resolution ultrasound imaging with multi-line transmission and filtered-delay multiply and sum beamforming

G Matrone, A Ramalli, AS Savoia… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Multi-Line Transmission (MLT) was recently demonstrated as a valuable tool to increase the
frame rate of ultrasound images. In this approach, the multiple beams that are …

High-frame-rate echocardiography using coherent compounding with Doppler-based motion-compensation

J Porée, D Posada, A Hodzic… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
High-frame-rate ultrasonography based on coherent compounding of unfocused beams can
potentially transform the assessment of cardiac function. As it requires successive waves to …

Architecture of an ultrasound system for continuous real-time high frame rate imaging

E Boni, L Bassi, A Dallai, V Meacci… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
High frame rate (HFR) imaging methods based on the transmission of defocused or plane
waves rather than focused beams are increasingly popular. However, the production of HFR …

High-frame-rate speckle-tracking echocardiography

P Joos, J Porée, H Liebgott, D Vray… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Conventional echocardiography is the leading modality for noninvasive cardiac imaging. It
has been recently illustrated that high-frame-rate echocardiography using diverging waves …

Ultrasound plane-wave imaging with delay multiply and sum beamforming and coherent compounding

G Matrone, AS Savoia, G Caliano… - 2016 38th Annual …, 2016 - ieeexplore.ieee.org
Improving the frame rate is an important aspect in medical ultrasound imaging, particularly in
3D/4D cardiac applications. However, an accurate trade-off between the higher frame rate …