Wind farms fault ride through using DFIG with new protection scheme

KE Okedu, SM Muyeen, R Takahashi… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
This paper proposes a control strategy of doubly fed induction generators (DFIGs) with new
protection schemes for enhancing fault ride through capability of wind farms composed of …

Comparative study of the effects of machine parameters on DFIG and PMSG variable speed wind turbines during grid fault

KE Okedu, M Al Tobi, S Al Araimi - Frontiers in Energy Research, 2021 - frontiersin.org
This study investigates the transient performance of two variable speed wind turbines
(VSWTs), namely doubly fed induction generator (DFIG) and the permanent magnet …

Augmentation of DFIG and PMSG wind turbines transient performance using different fault current limiters

KE Okedu - Energies, 2022 - mdpi.com
The technology of variable speed wind turbines is very promising in renewable power
generation. It is imperative for wind turbines to gain control after grid disturbances and …

Improvement of fault ride through capability of wind farms using DFIG considering SDBR

KE Okedu, SM Muyeen, R Takahashi… - Proceedings of the …, 2011 - ieeexplore.ieee.org
A new control strategy for improving fault ride-through capability of wind farms composed of
fixed and variable speed wind generators has been proposed, in this study. In this new …

A new control strategy for smoothing of wind farm output using short-term ahead wind speed prediction and Flywheel energy storage system

F Islam, H Hasanien, A Al-Durra… - 2012 American Control …, 2012 - ieeexplore.ieee.org
With the increased integration of wind energy into power networks it has become more
important to have a reliable system for mitigating the fluctuations of output power supplied to …

Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking …

KE Okedu, SM Muyeen - Energies, 2022 - mdpi.com
The recently stipulated grid codes require wind generators to re-initiate normal power
production after grid voltage sag. This paper presents a comparative performance of two …

Wind farm stabilization by using DFIG with current controlled voltage source converters taking grid codes into consideration

KE Okedu, R Takahashi, J Tamura - IEEJ Transactions on Power …, 2012 - jstage.jst.go.jp
Recent wind farm grid codes require wind generators to ride through voltage sags, which
means that normal power production should be re-initiated once the nominal grid voltage is …

Application of SDBR with DFIG to augment wind farm fault ride through

KE Okedu, SM Muyeen, R Takahashi… - … on Electrical Machines …, 2011 - ieeexplore.ieee.org
This paper proposes an application of series dynamic braking resistor (SDBR) connected to
the stator side of a doubly fed induction generator (DFIG), for enhancing fault ride through …

Protection schemes for DFIG considering rotor current and DC-link voltage

KE Okedu, SM Muyeen, R Takahashi… - … on Electrical Machines …, 2011 - ieeexplore.ieee.org
This paper presents new schemes for protecting power converters used in doubly fed
induction generator (DFIG) during a grid fault condition considering rotor current and DC-link …

Determination of the most effective switching signal and position of braking resistor in DFIG wind turbine under transient conditions

KE Okedu - Electrical Engineering, 2020 - Springer
A quick post fault recovery of wind generator system could be achieved with the help of a
series dynamic braking resistor (SDBR). This paper investigates the dynamics, size, optimal …