Inerter-based structural vibration control: A state-of-the-art review

R Ma, K Bi, H Hao - Engineering Structures, 2021 - Elsevier
Structural vibration control has received considerable research attentions in the past few
decades, with special emphasis on developing effective, affordable and applicable control …

Inerter-like devices used for vibration isolation: a historical perspective

WM Kuhnert, PJP Gonçalves… - Journal of the Franklin …, 2021 - Elsevier
Recently, a lot of attention has been given to a mechanical device known as the inerter. It is
a mechanical component that can be compared to a capacitor with two ungrounded …

Damping enhancement principle of inerter system

R Zhang, Z Zhao, C Pan, K Ikago… - Structural Control and …, 2020 - Wiley Online Library
Interactions among an inerter, spring, and energy dissipation element (EDE) in an inerter
system can result in a higher energy dissipation efficiency compared to a single identical …

Optimal design and seismic performance of Multi‐Tuned Mass Damper Inerter (MTMDI) applied to adjacent high‐rise buildings

D De Domenico, H Qiao, Q Wang… - The Structural Design …, 2020 - Wiley Online Library
The tuned mass damper inerter (TMDI) is an enhanced variant of the tuned mass damper
(TMD) that benefits from the mass‐amplification effect of the inerter. Here, a multi‐TMDI …

[HTML][HTML] Optimum double mass tuned damper inerter for control of structure subjected to ground motions

S Djerouni, M Abdeddaim, S Elias… - Journal of Building …, 2021 - Elsevier
Tuned mass damper inerter (TMDI) is commonly reported to be a lightweight tunable device
that can significantly reduce buildings' seismic response. However, the backward action …

[HTML][HTML] Optimal design and performance assessment of multiple tuned mass damper inerters to mitigate seismic pounding of adjacent buildings

S Djerouni, S Elias, M Abdeddaim… - Journal of Building …, 2022 - Elsevier
This work investigates the efficiency of tuned inerter dampers (TIDs) in controlling seismic
response of two adjacent buildings and the pounding distance between them. Pervious …

Optimum parameters of tuned inerter damper for damped structures

NU Islam, RS Jangid - Journal of Sound and Vibration, 2022 - Elsevier
This study evaluates optimal parameters for a damped system with a tuned inerter damper
(TID). TID is a device that works similarly to a tuned mass damper, except that the actual …

Study on wind-induced vibration control of linked high-rise buildings by using TMDI

Z Zhu, W Lei, Q Wang, N Tiwari, B Hazra - Journal of Wind Engineering and …, 2020 - Elsevier
Due to the aerodynamic interference of two closely-spaced linked high-rise buildings, large
out-of-phase vibrations of two buildings may be induced at across-wind direction. Tuned …

Robust distributed cruise control of multiple high-speed trains based on disturbance observer

X Wang, L Zhu, H Wang, T Tang… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
This paper investigates the robust distributed cruise control problem of multiple high-speed
trains under external disturbances. First, by modeling each train as a cascade of point …

Analytical optimization of the tuned viscous mass damper under impulsive excitations

Z Zhao, X Hu, R Zhang, Q Chen - International Journal of Mechanical …, 2022 - Elsevier
The inerter-based damper has proven as an efficient vibration suppression device for steady