A nanopower bandpass filter for detection of an acoustic signal in a wearable breathing detector
P Corbishley… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
This paper presents a nanopower programmable bandpass filter suitable to process
biomedical signals. The filter proves to be very robust to mismatch and process variations …
biomedical signals. The filter proves to be very robust to mismatch and process variations …
An ECG measurement IC using driven-right-leg circuit
In this paper, an electrocardiographic (ECG) signal processing IC, which is used for portable
biomedical application, was designed using continuous-time technique. The circuit consists …
biomedical application, was designed using continuous-time technique. The circuit consists …
Air brain: The easy telemetric system with smartphone for EEG signal and human behavior
K Honda, SN Kudoh - Proceedings of the 8th International Conference …, 2013 - dl.acm.org
Studies for human-machine interaction such as Brain-Computer Interface (BCI) using EEG
has been focused on. Usability in daily life is critical for BCI. Therefore, a convenient …
has been focused on. Usability in daily life is critical for BCI. Therefore, a convenient …
An EEG analog front-end design with wireless communication module for a portable EEG monitoring system
WC Chen, YC Chen, CC Chou… - 2015 IEEE 5th …, 2015 - ieeexplore.ieee.org
In this paper, a wireless electroencephalography (EEG) acquisition analog front-end (AFE)
circuit design is presented. The wireless EEG acquisition system includes an analog front …
circuit design is presented. The wireless EEG acquisition system includes an analog front …
Development of electroencephalography (EEG) data acquisition system based on FPGA PYNQ
This study proposed a novel Field Programmable Gate Array (FPGA)-based 32-channel
data acquisition system to acquire and process Electroencephalography (EEG) signal. The …
data acquisition system to acquire and process Electroencephalography (EEG) signal. The …
A novel readout chip with extendability for multi-channel EEG measurement
YC Chen, CH Tsai, ZH Hsieh… - 2013 IEEE International …, 2013 - ieeexplore.ieee.org
This paper proposes an extendable front-end readout chip (EFRC) for
electroencephalography (EEG) measurements. An EFRC is developed for EEG …
electroencephalography (EEG) measurements. An EFRC is developed for EEG …
Analysis and design of on-sensor ECG processors for realtime detection of cardiac anomalies including VF, VT, and PVC
HH Chen, CY Chiang, TC Chen, CS Liu… - Journal of Signal …, 2011 - Springer
Cardiovascular disease remains the main cause of death, and great efforts are spent on the
design of ECG (electrocardiogram) body sensors these years. Essential components such …
design of ECG (electrocardiogram) body sensors these years. Essential components such …
Low power low noise analog front-end IC design for biomedical sensor interface
Z Xiaodan - 2010 - scholarbank.nus.edu.sg
In the ageing society, the focus of the future healthcare services is moving from treatment to
prevention. Wearable health monitoring system is a possible solution to build the prevention …
prevention. Wearable health monitoring system is a possible solution to build the prevention …
A NIR CMOS preamplifier with DC photocurrent rejection for pulsed light source
AKY Wong, KP Pun, YT Zhang… - 2006 IEEE Biomedical …, 2006 - ieeexplore.ieee.org
A micro-power transimpedance amplifier is presented to acquire modulated optical signal for
heart-rate measurement. The circuit is composed of a transimpedance amplifier (TIA), a …
heart-rate measurement. The circuit is composed of a transimpedance amplifier (TIA), a …
[PDF][PDF] Memristor-Enabled Reconfigurable Integrated Circuits
G Papandroulidakis - academia.edu
The holy grail of analogue integrated circuit design is adjustable analogue delay elements.
Of course, all analogue circuits are filters. Internal delays impose overall low-pass character …
Of course, all analogue circuits are filters. Internal delays impose overall low-pass character …