Restenosis following implantation of bare metal coronary stents: pathophysiology and pathways involved in the vascular response to injury

NA Scott - Advanced drug delivery reviews, 2006 - Elsevier
This review summarizes the restenotic process that occurs after the implantation of bare
metal coronary stents. The pathology of in-stent restenosis is distinct from that seen after …

Stented artery flow patterns and their effects on the artery wall

N Duraiswamy, RT Schoephoerster… - Annu. Rev. Fluid …, 2007 - annualreviews.org
Stent design and geometry influence the fluid mechanical environment in an artery and
hence affect clinical outcomes of restenosis. There is clearly a role for biomechanics in …

A novel robot-assisted endovascular catheterization system with haptic force feedback

S Guo, Y Song, X Yin, L Zhang… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
The robot-assisted endovascular catheterization system (RAECS) has the potential to
address some of the procedural challenges and separate interventionalists from the X-ray …

Predictors of long-term outcome after crush stenting of coronary bifurcation lesions: importance of the bifurcation angle

V Dzavik, R Kharbanda, J Ivanov, DJ Ing, S Bui… - American heart …, 2006 - Elsevier
OBJECTIVES: We hypothesized that the bifurcation angle (BA) may affect the outcome of
crush stenting (CS) of bifurcation lesions and thus set out to determine the effect of the BA on …

Multilaboratory particle image velocimetry analysis of the FDA benchmark nozzle model to support validation of computational fluid dynamics simulations

P Hariharan, M Giarra, V Reddy, SW Day… - 2011 - asmedigitalcollection.asme.org
This study is part of a FDA-sponsored project to evaluate the use and limitations of
computational fluid dynamics (CFD) in assessing blood flow parameters related to medical …

Biological structural study of emerging shaped nanoparticles for the blood flow in diverging tapered stenosed arteries to see their application in drug delivery

NS Akbar, MB Habib, M Rafiq, T Muhammad… - Scientific Reports, 2024 - nature.com
The magnetic force effects and differently shaped nano-particles in diverging tapering
arteries having stenoses are being studied in current research via blood flow model. There …

Comparison of two stents in modifying cerebral aneurysm hemodynamics

M Kim, DB Taulbee, M Tremmel, H Meng - Annals of biomedical …, 2008 - Springer
There is a general lack of quantitative understanding about how specific design features of
endovascular stents (struts and mesh design, porosity) affect the hemodynamics in …

Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal …

JF LaDisa Jr, LE Olson, I Guler… - Journal of applied …, 2004 - journals.physiology.org
Restenosis limits the effectiveness of stents, but the mechanisms responsible for this
phenomenon remain incompletely described. Stent geometry and expansion during …

Luminal flow patterns dictate arterial drug deposition in stent-based delivery

VB Kolachalama, AR Tzafriri, DY Arifin… - Journal of Controlled …, 2009 - Elsevier
Endovascular stents reside in a dynamic flow environment and yet the impact of flow on
arterial drug deposition after stent-based delivery is only now emerging. We employed …

In vitro biomodels in stenotic arteries to perform blood analogues flow visualizations and measurements: A review

VM Carvalho, I Maia, A Souza, JE Ribeiro, P Costa… - 2020 - bibliotecadigital.ipb.pt
Cardiovascular diseases are one of the leading causes of death globally and the most
common pathological process is atherosclerosis. Over the years, these cardiovascular …