[HTML][HTML] The evolution of image reconstruction for CT—from filtered back projection to artificial intelligence
MJ Willemink, PB Noël - European radiology, 2019 - Springer
The first CT scanners in the early 1970s already used iterative reconstruction algorithms;
however, lack of computational power prevented their clinical use. In fact, it took until 2009 …
however, lack of computational power prevented their clinical use. In fact, it took until 2009 …
Domain progressive 3D residual convolution network to improve low-dose CT imaging
The wide applications of X-ray computed tomography (CT) bring low-dose CT (LDCT) into a
clinical prerequisite, but reducing the radiation exposure in CT often leads to significantly …
clinical prerequisite, but reducing the radiation exposure in CT often leads to significantly …
Discriminative feature representation to improve projection data inconsistency for low dose CT imaging
In low dose computed tomography (LDCT) imaging, the data inconsistency of measured
noisy projections can significantly deteriorate reconstruction images. To deal with this …
noisy projections can significantly deteriorate reconstruction images. To deal with this …
Self-supervised dynamic CT perfusion image denoising with deep neural networks
Dynamic computed tomography perfusion (CTP) imaging is a promising approach for acute
ischemic stroke diagnosis and evaluation. Hemodynamic parametric maps of cerebral …
ischemic stroke diagnosis and evaluation. Hemodynamic parametric maps of cerebral …
Image quality and dose characteristics for an O‐arm intraoperative imaging system with model‐based image reconstruction
Purpose To assess the imaging performance and radiation dose characteristics of the O‐
arm CBCT imaging system (Medtronic Inc., Littleton MA) and demonstrate the potential for …
arm CBCT imaging system (Medtronic Inc., Littleton MA) and demonstrate the potential for …
Regularization analysis and design for prior-image-based X-ray CT reconstruction
Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for
radiation dose reduction in computed tomography applications. PIBR methods take …
radiation dose reduction in computed tomography applications. PIBR methods take …
Assessment of prior image induced nonlocal means regularization for low‐dose CT reconstruction: change in anatomy
Purpose Repeated computed tomography (CT) scans are prescribed for some clinical
applications such as lung nodule surveillance. Several studies have demonstrated that …
applications such as lung nodule surveillance. Several studies have demonstrated that …
Low-dose CT reconstruction method based on prior information of normal-dose image
Z Chen, Q Zhang, C Zhou, M Zhang… - Journal of X-ray …, 2020 - content.iospress.com
BACKGROUND: Radiation risk from computed tomography (CT) is always an issue for
patients, especially those in clinical conditions in which repeated CT scanning is required …
patients, especially those in clinical conditions in which repeated CT scanning is required …
Low-dose CT perfusion of the liver using reconstruction of difference
Liver CT perfusion (CTP) is used in the detection, staging, and treatment response analysis
of hepatic diseases. Unfortunately, CTP radiation exposures are significant, limiting more …
of hepatic diseases. Unfortunately, CTP radiation exposures are significant, limiting more …