Non-destructive evaluation for corrosion monitoring in concrete: A review and capability of acoustic emission technique

A Zaki, HK Chai, DG Aggelis, N Alver - Sensors, 2015 - mdpi.com
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion process could help limit the location and …

Early corrosion detection in prestressed concrete girders using acoustic emission

MK ElBatanouny, J Mangual, PH Ziehl… - Journal of Materials in …, 2014 - ascelibrary.org
Long-term corrosion tests were performed on prestressed T-girders measuring 4.98 m (16 ft,
4 in.). The test program was composed of four specimens, including one control. The …

An Auto-Calibration Algorithm for Hybrid Guided Wave Tomography Based on Full Waveform Inversion

J Wen, C Jiang, Y Li, H Chen, W Ma, J Wang - IEEE Access, 2023 - ieeexplore.ieee.org
Combining with the dispersion characteristics of ultrasonic guided waves, full waveform
inversion method shows great application potential in the quantificational detections of …

Evaluation of concrete degradation using acoustic emission: Data filtering and damage detection

MA Abdelrahman - 2016 - search.proquest.com
The prevalent presence of aging and deteriorating infrastructure in the US has raised
concerns regarding its level of serviceability, reliability and vulnerability to natural disasters …

Implementation of acoustic emission as a non-destructive evaluation method for concrete structures

MK ElBatanouny - 2012 - search.proquest.com
Assessing the condition of in-service concrete bridges has recently gained significant
concern from both public and private entities. This is a direct result of the aging infrastructure …

[PDF][PDF] Corrosion detection of steel reinforcements of reinforced concrete structures using distributed long gauge sensors

N Fouad, MA Saifeldeen, H Huang, Z Wu - researchgate.net
This paper presents a new approach in corrosion monitoring system of steel rebar in
reinforced concrete (RC) flexural structures based on distributed long-gauge sensors. Three …

Assessment of flexural behaviour of concrete beam with corroded steel rebar using acoustic emission technique/Ahmad Zaki

Z Ahmad - 2018 - studentsrepo.um.edu.my
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion could help limit the location and the extent …

Assessment of Flexural Behaviour of Concrete Beam with Corroded Steel Rebar Using Acoustic Emission Technique

A Zaki - 2018 - search.proquest.com
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion could help limit the location and the extent …