Four decades of Fontan palliation
MR De Leval, JE Deanfield - Nature Reviews Cardiology, 2010 - nature.com
The Fontan palliation was introduced in 1968 to treat cardiac malformations unsuitable for
biventricular repair. This procedure has transformed the surgical management of congenital …
biventricular repair. This procedure has transformed the surgical management of congenital …
[HTML][HTML] Cavopulmonary assist for the univentricular Fontan circulation: von Karman viscous impeller pump
MD Rodefeld, B Coats, T Fisher, GA Giridharan… - The Journal of thoracic …, 2010 - Elsevier
OBJECTIVE: In a univentricular Fontan circulation, modest augmentation of existing
cavopulmonary pressure head (2–5 mm Hg) would reduce systemic venous pressure …
cavopulmonary pressure head (2–5 mm Hg) would reduce systemic venous pressure …
Fluid–structure interaction analysis of flexible turbomachinery
RL Campbell, EG Paterson - Journal of Fluids and Structures, 2011 - Elsevier
A method for the performance computation of an expandable-impeller pump is developed
and validated. Large deformations of the highly flexible pump impellers result in a strong …
and validated. Large deformations of the highly flexible pump impellers result in a strong …
Long-term issues after the Fontan procedure
ME McRae - AACN advanced critical care, 2013 - AACN
The Fontan procedure is used to treat various serious congenital heart defects. Although
many people who have had the procedure live productively into adulthood, as they age, they …
many people who have had the procedure live productively into adulthood, as they age, they …
An artificial right ventricle for failing Fontan: in vitro and computational study
FG Lacour-Gayet, CJ Lanning, S Stoica, R Wang… - The Annals of thoracic …, 2009 - Elsevier
BACKGROUND: The aim of this study is to develop a destination low-pressure artificial right
ventricle (ARV) to correct the impaired hemodynamics in the failing Fontan circulation …
ventricle (ARV) to correct the impaired hemodynamics in the failing Fontan circulation …
[HTML][HTML] In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients
Background Palliative repair of single ventricle defects involve a series of open-heart
surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages …
surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages …
Chronic in vivo test of a right heart replacement blood pump for failed Fontan circulation
J Cysyk, JB Clark, R Newswanger, CS Jhun, J Izer… - ASAIO …, 2019 - journals.lww.com
An implantable rotary blood pump was developed to provide long-term mechanical right
heart support for patients who have failing Fontan circulation. The objective of this study was …
heart support for patients who have failing Fontan circulation. The objective of this study was …
Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios
O Dur, M Lara, D Arnold, S Vandenberghe… - Artificial …, 2009 - Wiley Online Library
The characteristic depressed hemodynamic state and gradually declining circulatory
function in Fontan patients necessitates alternative postoperative management strategies …
function in Fontan patients necessitates alternative postoperative management strategies …
Computational Investigation of Anastomosis Options of a Right-Heart Pump to Patient Specific Pulmonary Arteries
Patients with Fontan circulation have increased risk of heart failure, but are not always
candidates for heart transplant, leading to the development of the subpulmonic Penn State …
candidates for heart transplant, leading to the development of the subpulmonic Penn State …
Assisted Fontan procedure: animal and in vitro models and computational fluid dynamics study
Fontan connection with intermittent compression by wrapped latissimus dorsi (LD) was
tested in vivo, in vitro and by means of computational fluid dynamics (CFD). Experimental …
tested in vivo, in vitro and by means of computational fluid dynamics (CFD). Experimental …