Clinical Applications of Conebeam CTP Imaging in Cerebral Disease: A Systematic Review

AHAZ Al-Kaylani, RCL Schuurmann… - American Journal …, 2023 - Am Soc Neuroradiology
BACKGROUND: Perfusion imaging with multidetector CT is integral to the evaluation of
patients presenting with ischemic stroke due to large-vessel occlusion. Using conebeam CT …

Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral …

T Struffert, Y Deuerling-Zheng… - American Journal …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The viability of both brain parenchyma and vascular
anatomy is important in estimating the risk and potential benefit of revascularization in …

Toward a novel soft robotic system for minimally invasive interventions

N Barnes, O Young, A Colton, X Liu… - International journal of …, 2023 - Springer
Purpose During minimally invasive surgery, surgeons maneuver tools through complex
anatomies, which is difficult without the ability to control the position of the tools inside the …

The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): a phantom study

M Bai, B Liu, H Mu, X Liu, Y Jiang - European journal of radiology, 2012 - Elsevier
PURPOSE: To assess and compare the radiation dose of DynaCT in phantoms to that of
MSCT. METHODS AND MATERIALS: A male Anderson Radiation Therapy 200 phantom …

Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application

NV Patel, MJ Gounis, AK Wakhloo… - American journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: With modern imaging techniques, visualization of
neurovascular stents remains challenging. We present a method for contrast-enhanced C …

Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

AS Wang, JW Stayman, Y Otake… - Physics in Medicine …, 2014 - iopscience.iop.org
The potential for statistical image reconstruction methods such as penalized-likelihood (PL)
to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging …

Flat detector CT with cerebral pooled blood volume perfusion in the angiography suite: from diagnostics to treatment monitoring

T van der Zijden, A Mondelaers, M Voormolen… - Diagnostics, 2022 - mdpi.com
C-arm flat-panel detector computed tomographic (CT) imaging in the angiography suite
increasingly plays an important part during interventional neuroradiological procedures. In …

Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation framework

TP Szczykutowicz, CA Mistretta - Medical physics, 2013 - Wiley Online Library
Purpose: The purpose of this work is to introduce a new device that allows for patient‐
specific imaging‐dose modulation in conventional and cone‐beam CT. The device is called …

Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

B Schulz, K Eichler, P Siebenhandl, T Gruber-Rouh… - European …, 2013 - Springer
Objective To analyse the feasibility and accuracy of robotic aided interventions on a
phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) …

Clinical significance and prevalence of subarachnoid hyperdensities on flat detector CT after mechanical thrombectomy: does it really matter?

M Zidan, S Ghaei, FJ Bode, JM Weller… - Journal of …, 2024 - jnis.bmj.com
Background Subarachnoid hyperdensities after mechanical thrombectomy (MT) are a
common finding. However, it is often regarded as clinically insignificant. Objective With this …