Dosimetry of ionising radiation in modern radiation oncology

T Kron, J Lehmann, PB Greer - Physics in Medicine & Biology, 2016 - iopscience.iop.org
Dosimetry of ionising radiation is a well-established and mature branch of physical sciences
with many applications in medicine and biology. In particular radiotherapy relies on …

Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions

IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …

Small-field radiotherapy photon beam output evaluation: Detectors reviewed

SE Lam, DA Bradley, MU Khandaker - Radiation Physics and Chemistry, 2021 - Elsevier
Small fields (few cm and below) are being applied in therapy independently or as mm/sub-
cm segments of larger fields. Included are intensity modulated radiotherapy …

Detector dose response in megavoltage small photon beams. I. Theoretical concepts

H Bouchard, J Seuntjens, S Duane, Y Kamio… - Medical …, 2015 - Wiley Online Library
Purpose: To explain the reasons for significant quality correction factors in megavoltage
small photon fields and clarify the underlying concepts relevant to dosimetry under such …

Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects

H Bouchard, Y Kamio, H Palmans, J Seuntjens… - Medical …, 2015 - Wiley Online Library
Purpose: To quantify detector perturbation effects in megavoltage small photon fields and
support the theoretical explanation on the nature of quality correction factors in these …

Dosimetry of cone‐defined stereotactic radiosurgery fields with a commercial synthetic diamond detector

JE Morales, SB Crowe, R Hill, N Freeman… - Medical …, 2014 - Wiley Online Library
Purpose: Small field x‐ray beam dosimetry is difficult due to lack of lateral electronic
equilibrium, source occlusion, high dose gradients, and detector volume averaging …

Determination of topographical radiation dose profiles using gel nanosensors

K Pushpavanam, S Inamdar, S Dutta, T Bista… - Science …, 2019 - science.org
Despite the emergence of sophisticated technologies in treatment planning and
administration, routine determination of delivered radiation doses remains a challenge due …

Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system

S Tanny, N Sperling, EI Parsai - Medical physics, 2015 - Wiley Online Library
Purpose: Accurate dosimetry of small fields remains a challenge to the clinical physicist.
Choosing the appropriate detector and determination of factors continue to be an area of …

Validity of equivalent square field concept in small field dosimetry

IJ Das, SK Dogan, M Gopalakrishnan, GX Ding… - Medical …, 2022 - Wiley Online Library
Purpose The equivalent square (ES) concept has been used for traditional radiation fields
defined by the machine collimating system. For small fields, the concept Sclin was …

Assessment of beam‐matched linacs quality/accuracy for interchanging SBRT or SRT patient using VMAT without replanning

Z Xu, G Warrell, S Lee, V Colussi… - Journal of applied …, 2019 - Wiley Online Library
Purpose Dosimetric accuracy is critical when switching a patient treated with stereotactic
body radiation therapy (SBRT) or stereotactic fractionated radiotherapy (SRT) among beam …