Design, Fabrication & Evaluation of a New Calibration Phantom for In vivo Measurement of Bone-seeking Radionuclides
HB Spitz, J Lodwick - Radiation protection dosimetry, 2000 - academic.oup.com
A new anthropometric phantom has been developed for use in calibrating in vivo
measurements of bone-seeking radionuclides. The phantom has the external shape and …
measurements of bone-seeking radionuclides. The phantom has the external shape and …
Calculation and Measurement of Calibration Factors for Bone-Surface Seeking Low Energy Gamma Emitters and Determination of 241Am Activity in a Real Case of …
JG Hunt, I Malátová, S Foltánová - Radiation protection …, 1999 - academic.oup.com
A voxel phantom has been developed to simulate in vivo measurement systems for
calibration purposes. The calibration method presented here employs a mathematical …
calibration purposes. The calibration method presented here employs a mathematical …
Monte Carlo modelling of a voxel head phantom for in vivo measurement of bone-seeker nuclides
G Gualdrini, C Daffara, KW Burn… - Radiation protection …, 2005 - academic.oup.com
Whole-body counters (WBCs) are used for the assessment of the internal contamination of
actinides in the human body. WBCs require adequate calibration procedures that rely on the …
actinides in the human body. WBCs require adequate calibration procedures that rely on the …
Reconstruction of a human skull calibration phantom using bone sections from an 241Am exposure case
DP Hickman, N Cohen - Health physics, 1988 - journals.lww.com
Abstract New York University Medical Center's Institute of Environmental Medicine
(NYUMC/IEM) was called upon by representatives of the United States Transuranic Registry …
(NYUMC/IEM) was called upon by representatives of the United States Transuranic Registry …
A MCNP-based calibration method and a voxel phantom for in vivo monitoring of 241Am in skull
Whole body counter (WBC) facilities are currently used for assessment of internal
radionuclide body burdens by directly measuring the radiation emitted from the body …
radionuclide body burdens by directly measuring the radiation emitted from the body …
Assessment of the internal dose of 241Am in bone by in vivo measurements of activity deposited in knee
JF Navarro, MA Lopez, T Navarro… - Radiation protection …, 2007 - academic.oup.com
In case of chronic exposure or long time after an acute intake of 241Am as a consequence of
an incident, the assessment of internal dose might be realised by estimating the total activity …
an incident, the assessment of internal dose might be realised by estimating the total activity …
Intercomparison Exercise for the Determination of 241Am in the Human Skeleton
W Rühm, K König, I Malátová, H Doerfel… - Radiation protection …, 1998 - academic.oup.com
Abstract 241Am is known to be a bone-seeking isotope. In the long term it enters the human
skeleton. In this paper, the case of a now 62 year old male subject who incorporated 241Am …
skeleton. In this paper, the case of a now 62 year old male subject who incorporated 241Am …
A summary of the proceedings of the workshop on standard phantoms for in vivo radioactivity measurement
GH Kramer, KGW Inn - Health physics, 1991 - journals.lww.com
IN MID-FEBRUARY 1990, the National Institute of Standards and Technology (NIST) and the
Bureau of Radiation and Medical Devices (BRMD) organized a 3-d workshop in an attempt …
Bureau of Radiation and Medical Devices (BRMD) organized a 3-d workshop in an attempt …
Development and characterisation of a head calibration phantom for in vivo measurements of actinides
G Gualdrini, P Battisti, R Biagini, P De Felice… - Applied Radiation and …, 2000 - Elsevier
The investigation of actinides' internal contamination in human body makes use of a variety
of techniques. In large scale screening the technique of “in vivo” evaluation of bone 241Am …
of techniques. In large scale screening the technique of “in vivo” evaluation of bone 241Am …
Anthropomorphic phantom with strontium-90 incorporated in the skeleton
AN Kovtun, AG Puzikov, AI Sokolov… - Radiation protection …, 2000 - academic.oup.com
A calibration phantom with incorporated 90Sr has been designed and made completely of
tissue-substitute materials. This phantom fills a unique niche in the metrological support for …
tissue-substitute materials. This phantom fills a unique niche in the metrological support for …