[HTML][HTML] Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory

M Usman, B Ruijsink, MS Nazir, G Cruz… - Magnetic resonance …, 2017 - Elsevier
Purpose To present a method that uses a novel free-running self-gated acquisition to
achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI. Material and …

Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function

J Liu, L Feng, HW Shen, C Zhu, Y Wang… - … Resonance Materials in …, 2017 - Springer
Objective This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac
cine MRI method for cardiac function assessment. Materials and methods A golden-ratio …

Fully self‐gated free‐running 3D Cartesian cardiac CINE with isotropic whole‐heart coverage in less than 2 min

T Küstner, A Bustin, O Jaubert… - NMR in …, 2021 - Wiley Online Library
Purpose To develop a novel fast water‐selective free‐breathing 3D Cartesian cardiac CINE
scan with full self‐navigation and isotropic whole‐heart (WH) coverage. Methods A free …

Free‐breathing cine imaging with motion‐corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self‐gating (SPARCS)

R Zhou, Y Yang, RC Mathew… - Magnetic resonance …, 2019 - Wiley Online Library
Purpose To develop a continuous‐acquisition cardiac self‐gated spiral pulse sequence and
a respiratory motion‐compensated reconstruction strategy for free‐breathing cine imaging …

Free‐breathing imaging of the heart using 2D cine‐GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and …

PA Vuissoz, F Odille, B Fernandez… - Journal of Magnetic …, 2012 - Wiley Online Library
Purpose: To assess cardiac function by means of a novel free‐breathing cardiac magnetic
resonance imaging (MRI) strategy. Materials and Methods: A stack of ungated 2D steady …

2D free‐breathing dual navigator‐gated cardiac function validated against the 2D breath‐hold acquisition

DC Peters, R Nezafat, H Eggers… - Journal of Magnetic …, 2008 - Wiley Online Library
Purpose To develop and validate a free‐breathing cardiac cine acquisition, with potential to
simplify cardiac MR studies, provide registered slices, and increase spatial resolution …

Manifold learning based ECG‐free free‐breathing cardiac CINE MRI

M Usman, D Atkinson, C Kolbitsch… - Journal of magnetic …, 2015 - Wiley Online Library
Purpose To present and validate a manifold learning (ML)‐based method that can estimate
both cardiac and respiratory navigator signals from electrocardiogram (ECG)‐free free …

Free‐breathing whole‐heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation

MH Moghari, A Barthur, ME Amaral… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose To develop and validate a new prospective respiratory motion compensation
algorithm for free‐breathing whole‐heart 3D cine steady‐state free precession (SSFP) …

3D breath‐held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI

DC Peters, DB Ennis, P Rohatgi… - Journal of Magnetic …, 2004 - Wiley Online Library
Purpose To develop and validate a three‐dimensional (3D) single breath‐hold, projection
reconstruction (PR), balanced steady state free precession (SSFP) method for cardiac …

Isotropic 3D Cartesian single breath‐hold CINE MRI with multi‐bin patch‐based low‐rank reconstruction

T Küstner, A Bustin, O Jaubert… - Magnetic resonance …, 2020 - Wiley Online Library
Purpose To develop a novel acquisition and reconstruction framework for isotropic 3D
Cartesian cardiac CINE within a single breath‐hold for left ventricle (LV) and whole‐heart …