Blood pressure measurement by arterial tonometry in controlled hypotension

O Kemmotsu, M Ueda, H Otsuka… - Anesthesia & …, 1991 - journals.lww.com
… that arterial tonometry can reduce the need for conventional, invasive IBP monitoring methods
during controlled hypotension as … This is especially true if the tonometer is used with pulse …

Accuracy of a continuous blood pressure monitor based on arterial tonometry.

T Sato, M Nishinaga, A Kawamoto, T Ozawa… - …, 1993 - Am Heart Assoc
pressure. Our interests in the comparison of the blood pressures measured by the two
methods were focused on the following … in controlled hypotension. Anesth Analg 1991:73:54-58 …

Comparison of blood pressure monitoring by applanation tonometry and invasively assessed blood pressure in cardiological patients

G Greiwe, S Hoffmann, L Herich, MS Winkler… - … of Clinical Monitoring …, 2018 - Springer
… of non-invasive continuous blood pressure measurement by applanation tonometry (AT) in
awake … Arterial blood pressure was recorded by applanation tonometry (T-Line 400, Tensys …

Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?

MR Nelson, J Stepanek, M Cevette, M Covalciuc… - Mayo Clinic …, 2010 - Elsevier
blood pressure measurements may be overcome with AT. Tonometry of the radial artery
provides an accurate, reproducible, noninvasive assessment of the central pulse pressure (…

Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement

J Harju, A Vehkaoja, P Kumpulainen… - … of clinical monitoring …, 2018 - Springer
… may be an alternative for fast and continuous measurement. Our aim was to compare arterial
tonometry sensor (BPro ® ) with invasive blood pressure measurement to clarify whether it …

[HTML][HTML] Techniques for non-invasive monitoring of arterial blood pressure

AS Meidert, B Saugel - Frontiers in medicine, 2018 - frontiersin.org
… A device allowing automated radial artery applanation tonometry is the T-Line system (Tensys
Medical, San Diego, CA, USA) (15, 16). The system has been evaluated in various clinical …

Measurement of blood pressure

B Saugel, R Dueck, JY Wagner - Best Practice & Research Clinical …, 2014 - Elsevier
… order to avoid unreliable blood pressure measurements and consequential treatment … blood
pressure recording such as the volume clamp method or radial artery applanation tonometry

Noninvasive and continuous blood pressure measurement via superficial temporal artery tonometry

J Canning, K Helbert, G Iashin… - 2016 38th Annual …, 2016 - ieeexplore.ieee.org
… a custom control and monitoring interface on … measurement. Preliminary testing of the device
showed a percentage error from a blood pressure cuff mean arterial pressure measurement

… the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements …

AS Meidert, W Huber, A Hapfelmeier, M Schöfthaler… - Journal of critical …, 2013 - Elsevier
Blood pressure changes of 3 mm Hg or less were excluded from … ratio: arterial tonometry
and invasive BP measurements that … blood pressure device during induced hypotension

Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit

N Langwieser, L Prechtl, AS Meidert… - Clinical Research in …, 2015 - Springer
… (b), and diastolic arterial pressure (c). The slim continuous lines indicate the non-… of
arterial blood pressure measurements (with radial artery applanation tonometry and the arterial