CT coronary angiography: image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection

R Wang, UJ Schoepf, R Wu, KP Gibbs, W Yu, M Li… - Clinical radiology, 2013 - Elsevier
… It has been demonstrated that iterative reconstruction algorithms can improve image quality
filtered back-projection (FBP) approach.8, 9 Sinogram-affirmed iterative reconstruction (…

Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection

R Wang, UJ Schoepf, R Wu, RP Reddy, C Zhang… - European journal of …, 2012 - Elsevier
… The coronary artery image quality scores, image noise, SNR and CNR were not … to filtered
back-projection (FBP), the application of SAFIRE at CTCA provides superior image quality and …

Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique …

A Moscariello, RAP Takx, UJ Schoepf, M Renker… - European …, 2011 - Springer
Filtered back projection and iterative reconstructions were … (>50%) coronary artery
stenosis using the American Heart … evaluation of sinogram-affirmed iterative reconstruction, a …

Diagnostic accuracy of coronary CT angiography: comparison of filtered back projection and iterative reconstruction with different strengths

R Wang, UJ Schoepf, R Wu, JW Nance Jr… - Journal of computer …, 2014 - journals.lww.com
Sinogram-affirmed iterative reconstruction strength factor 3 … with filtered back projection (FBP),
the application of iterative … The optimal compromise between image quality and diagnostic …

… between advanced modelled iterative reconstruction (ADMIRE), sinogram affirmed iterative reconstruction (SAFIRE) and filtered back projection (FBP) in one patients' …

A Örgel, G Bier, F Hennersdorf, H Richter… - Clinical …, 2020 - Springer
… traditional filtered back projection (FBP) algorithm for image … the image quality of the
two IR techniques Sinogram-affirmed … ) and advanced modelled iterative reconstruction (ADMIRE, …

Reduced-dose low-voltage chest CT angiography with Sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection

F Pontana, J Pagniez, A Duhamel, T Flohr, JB Faivre… - Radiology, 2013 - pubs.rsna.org
image quality of low-voltage chest CT angiography with raw-data-based iterative reconstruction
in comparison with image quality of … standard-voltage filtered back projection (FBP) CT. …

Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

RAP Takx, UJ Schoepf, A Moscariello, M Das… - European Journal of …, 2013 - Elsevier
filtered back projection (FBP) 20% tube current datasets. … using iterative reconstruction
(Sinogram Affirmed Iterative … to observe its effects on image quality in comparison to traditional …

Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction

M Renker, JW Nance Jr, UJ Schoepf, TX O'Brien… - Radiology, 2011 - pubs.rsna.org
… current standard CT image reconstruction technique is filtered back projection (… Iterative
reconstruction techniques have been proposed for over 3 decades to improve CT image quality

… quality, diagnostic value and radiation dose of coronary CT angiography using iterative reconstruction compared to filtered back projection in the diagnosis of coronary …

AA Shammakhi, Z Sun - Journal of Medical Imaging and Health …, 2015 - ingentaconnect.com
Iterative reconstruction technique leads to noise reduction … improvement in image quality in
coronary CT angiography with … standard filtered back projection in coronary CT angiography, …

Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and …

Q Jia, J Zhuang, J Jiang, J Li, M Huang… - European journal of …, 2017 - Elsevier
images reconstructed using the filtered back projectioncoronary artery visibility in infants
than did iDose 4 in infants. The exact cause of this slightly poorer coronary artery image quality