Malpositioned peritoneal dialysis catheters: a critical reappraisal of correction by stiff-wire manipulation

JS Moss, SA Minda, GE Newman, NR Dunnick… - … Journal of Kidney …, 1990 - Elsevier
… Three of these six catheters again malpositioned. We conclude that stiff-wire manipulation is
… safe technique worth using on a limited basis for the initial episode of catheter malposition. …

Correction of displaced peritoneal dialysis catheters with an angular stiff rod

U Ozyer, A Harman, C Aytekin, F Boyvat… - Acta …, 2009 - Taylor & Francis
… and a stiff wire under fluoroscopy guidance, catheters that had … Stiff guidewire manipulation
of migrated CAPD catheters has … to surgical correction). The success rates of stiff guidewire …

Guide wire directed manipulation of malfunctioning peritoneal dialysis catheters: a critical analysis

SJ Savader, G Lund, PJ Scheel, C Prescott… - Journal of vascular and …, 1997 - Elsevier
… CAPD catheter malfunction due to malpositioning, peritoneal adhesions, or a one-way … at
least partially correctable by guide wire manipulations that might disrupt either and "freeup" the …

Fluoroscopically-guided manipulation of malfunctioning peritoneal dialysis catheters

ME Simons, G Pron, M Voros… - Peritoneal dialysis …, 1999 - journals.sagepub.com
Malpositioned peritoneal dialysis catheters: a critical reappraisal of correction by stiff-wire
manipulation. Am J … Stiff wire manipulation of peritoneal dialysis catheters. In: Khanna R, ed. Ad…

Tenckhoff catheter salvage by closed stiff-wire manipulation without fluoroscopic control

B Jones, K McLaughlin, RA Mactier… - Peritoneal dialysis …, 1998 - journals.sagepub.com
malposition of straight two-cuff Tenckhoff catheters. .Interventions: Closed stiff-wire manipulation
of malpositioned Tenckhoff catheter … wire and catheter drawn into the correct position in …

Fluoroscopic guide wire manipulation of malfunctioning peritoneal dialysis catheters initially placed by interventional radiologists

YH Kwon, SH Kwon, JH Oh, KH Jeong… - Journal of Vascular and …, 2014 - Elsevier
… using a stiff wire (3, 4, 5, 14, 15), a malleable aluminum bar (… straight-type PD catheter tip is
upwardly displaced out of the … that is not easily corrected by percutaneous manipulation. Late …

Management of peritoneal catheter malfunction

JA Diaz-Buxo - Peritoneal Dialysis International, 1998 - journals.sagepub.com
… surgery has been used for both inserting and correcting catheter malposition (16-25). …
Malpositioned peritoneal dialysis catheters: a critical reappraisal of correction by wire manipulation

Double guidewire method: a novel technique for correction of migrated Tenckhoff peritoneal dialysis catheter

CM Lee, SF Ko, HC Chen… - Peritoneal dialysis …, 2003 - journals.sagepub.com
correction of the migrated CAPD catheters was achieved in 19 (86%) patients. Two of these
19 patients needed a second manipulation because of remigration of the catheters after 3 …

Fluoroscopic manipulation is also useful for malfunctioning swan-neck peritoneal catheters

MM Plaza, MC Rivas… - Peritoneal dialysis …, 2001 - journals.sagepub.com
peritoneal dialysis. A new malposition occurred within 30 days after initial manipulation in 5
… In summary, fluoroscopic manipulation using a stiff wire has been described as a method of …

Peritoneal dialysis catheters: repositioning with new fluoroscopic technique.

RL Siegel, JL Nosher, LR Gesner - Radiology, 1994 - pubs.rsna.org
… Tenckhoff peritoneal dialysis catheter: cannutography and manipulation. … of catheter
malfunction during continuous ambulatory peritoneal dialysis. Dig Ohs Sci 1985; 30:465-467. 8. …