Rebound self-tonometry acquisition time and ease of use evaluated by newly trained optometry students and optometrists

R Hyatt, NM Furtado, D Eberle, K Jensen… - Optometry and Vision …, 2020 - journals.lww.com
… The purpose of this study was to measure the time needed for a nonclinical convenience
sample of optometry students and optometrists to self-measure IOP using Icare HOME and to …

Home self-tonometry trials compared with clinic tonometry in patients with glaucoma

EJ McGlumphy, A Mihailovic, PY Ramulu… - Ophthalmology …, 2021 - Elsevier
… the iCare HOME highlighted the ability of self-tonometry to capturereviewed the clinical
records of all 61 patients who underwent home self-tonometry using the iCare HOME rebound

Assessing the reliability of intraocular pressure measurements using rebound tonometry

T Realini, B McMillan, RL Gross, E Devience… - Journal of …, 2021 - journals.lww.com
… in this report was reviewed and approved by the West … The iCare HOME device has been
shown to be user-friendly in … a trained operator using the ic100 in the office and by the patient …

[PDF][PDF] Tonometry for the Management of Glaucoma

S Boone, K Grounds, J Lighthizer - 2012 - dashboard.digitallibrary.nsuok.edu
… IRB we recruited 31 optometry students who composed the study … This study tested if patient
self-tonometry with the ICare ONE … Evaluation of the Icare rebound tonometer as a home …

Inventing a Dual-Function Rebound Tonometer and Eyedrop Dispenser: A Synergistic Approach to Glaucoma Care

S Pollanen, R Syan - Aging and (Geron) Technology, 2024 - ojs.library.queensu.ca
… , with patients potentially requiring training to utilize the device correctly. Despite ease of use
and a design … Evaluation of a novel ab externo MicroShunt for the treatment of glaucoma. …

[图书][B] Self-Monitoring of Intraocular Pressure and its Clinical Application

L Quérat - 2022 - search.proquest.com
… of rebound tonometry in the late 1990s, new possibilities … the eye clinic or by optometrists
and opticians. A decade ago, a … was to evaluate the feasibility of self-tonometry by glaucoma …

Comparison of Intraocular Pressure (IOP) estimation by Perkins Tonometer done by Ophthalmic Assistant and Goldmann Applanation Tonometer done by …

R Lakshmi Malar - 2020 - repository-tnmgrmu.ac.in
… as a phychophysical test for self tonometry at home. The pencil… to a probe shaft that bounce
a magnetized probe off the … study assessed the agreement between trained optometrists

Collaborative care models and novel clinical methods for diagnosis and management of glaucoma

J Huang - 2020 - unsworks.unsw.edu.au
… collaborative care between optometrists and ophthalmologists. … New services have been
established between optometry … then rebounds from the cornea with faster rebound equating to …

[PDF][PDF] Intraocular pressure measurements using vibration based non-contact tonometry

R Farshidi - 2009 - prism.ucalgary.ca
… that ophthalmologists and optometrists use to estimate the … and the energy absorbed after
rebounding. This method of … used by the patient to allow selftonometry at home. The instrument …

Glaucoma and telemedicine

C Brandão-de-Resende, LAR de Alcântara… - Journal of …, 2023 - journals.lww.com
… the hospital eye service between an optometrist, with a special … saw patients in person,
acquired clinical history, performed a … facilities with highly trained technicians, optometrists and/or …