Dedicated breast computed tomography: basic aspects

A Sarno, G Mettivier, P Russo - Medical physics, 2015 - Wiley Online Library
X‐ray mammography of the compressed breast is well recognized as the “gold standard” for
early detection of breast cancer, but its performance is not ideal. One limitation of screening …

Dedicated breast CT: State of the art—Part II. Clinical application and future outlook

Y Zhu, AM O'Connell, Y Ma, A Liu, H Li, Y Zhang… - European …, 2022 - Springer
Dedicated breast CT is being increasingly used for breast imaging. This technique provides
images with no compression, removal of tissue overlap, rapid acquisition, and available …

Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT

J Bian, JH Siewerdsen, X Han, EY Sidky… - Physics in Medicine …, 2010 - iopscience.iop.org
Flat-panel-detector x-ray cone-beam computed tomography (CBCT) is used in a rapidly
increasing host of imaging applications, including image-guided surgery and radiotherapy …

Sparse-view spectral CT reconstruction using spectral patch-based low-rank penalty

K Kim, JC Ye, W Worstell, J Ouyang… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
Spectral computed tomography (CT) is a promising technique with the potential for
improving lesion detection, tissue characterization, and material decomposition. In this …

Anatomical background and generalized detectability in tomosynthesis and cone‐beam CT

GJ Gang, DJ Tward, J Lee, JH Siewerdsen - Medical physics, 2010 - Wiley Online Library
Purpose: Anatomical background presents a major impediment to detectability in 2D
radiography as well as 3D tomosynthesis and cone‐beam CT (CBCT). This article …

Breast ct

SJ Glick - Annu. Rev. Biomed. Eng., 2007 - annualreviews.org
Breast cancer is a serious disease that accounts for approximately 40,000 deaths per year in
the United States. Unfortunately, there is no known cause of breast cancer, and therefore the …

Advances in digital and physical anthropomorphic breast phantoms for x‐ray imaging

SJ Glick, LC Ikejimba - Medical physics, 2018 - Wiley Online Library
Purpose With the advent of three‐dimensional (3D) breast imaging modalities such as
digital breast tomosynthesis (DBT) and dedicated breast CT (bCT), research into new …

Noise, sampling, and the number of projections in cone‐beam CT with a flat‐panel detector

Z Zhao, GJ Gang, JH Siewerdsen - Medical physics, 2014 - Wiley Online Library
Purpose: To investigate the effect of the number of projection views on image noise in cone‐
beam CT (CBCT) with a flat‐panel detector. Methods: This fairly fundamental consideration …

Comparative power law analysis of structured breast phantom and patient images in digital mammography and breast tomosynthesis

L Cockmartin, H Bosmans, NW Marshall - Medical physics, 2013 - Wiley Online Library
Purpose: This work characterizes three candidate mammography phantoms with structured
background in terms of power law analysis in the low frequency region of the power …

Anatomical complexity in breast parenchyma and its implications for optimal breast imaging strategies

L Chen, CK Abbey, A Nosratieh, KK Lindfors… - Medical …, 2012 - Wiley Online Library
Purpose: The purpose of this investigation was to assess the anatomical noise in breast
images using a mathematically derived parameterβ as a surrogate for detection …