Assessment of change in body fat percentage with DXA and eight-electrode BIA in centrally obese women.
M Neovius, J Uddén, E Hemmingsson - Medicine and science in …, 2007 - europepmc.org
M Neovius, J Uddén, E Hemmingsson
Medicine and science in sports and exercise, 2007•europepmc.orgPurpose To compare estimates of change in percent body fat (Delta% BF) between DXA and
BIA8 in abdominally obese women. Methods Six-month longitudinal study of 106 women
(baseline: age 48.2+/-7.6 yr; BMI 30.4+/-2.9 kg. m;% BFDXA 45.8+/-3.6%) participating in an
exercise-oriented behavior-change program (walking and bicycling). Fatness was measured
by DXA and Tanita BC-418 (BIA8). Agreement between methods was assessed, and
regression analysis was used to find predictors of the deviation between methods for …
BIA8 in abdominally obese women. Methods Six-month longitudinal study of 106 women
(baseline: age 48.2+/-7.6 yr; BMI 30.4+/-2.9 kg. m;% BFDXA 45.8+/-3.6%) participating in an
exercise-oriented behavior-change program (walking and bicycling). Fatness was measured
by DXA and Tanita BC-418 (BIA8). Agreement between methods was assessed, and
regression analysis was used to find predictors of the deviation between methods for …
Purpose
To compare estimates of change in percent body fat (Delta% BF) between DXA and BIA8 in abdominally obese women.
Methods
Six-month longitudinal study of 106 women (baseline: age 48.2+/-7.6 yr; BMI 30.4+/-2.9 kg. m;% BFDXA 45.8+/-3.6%) participating in an exercise-oriented behavior-change program (walking and bicycling). Fatness was measured by DXA and Tanita BC-418 (BIA8). Agreement between methods was assessed, and regression analysis was used to find predictors of the deviation between methods for estimating changes in fat mass percentage.
Results
The methods differed significantly, both at baseline and follow-up (-5.0 and-4.4% BF, respectively; both P< 0.001). The mean Delta% BF was-1.1+/-2.5% BFDXA and-0.5+/-2.2% BFBIA8 (mean difference between methods 0.6+/-1.8% BF; P< 0.001; 95% limits of agreement-3.0 to 4.2% BF), with a range of-14.8 to 3.3% BFDXA and-9.4 to 3.5% BFBIA8. Approximately 49% of the variation in the difference between methods was explained by variations in age (beta=-0.05; P= 0.006), DeltaBMI (beta= 0.98; P< 0.001), and Delta% BFDXA (beta=-0.71; P< 0.001), indicating that the larger the change, the greater the discrepancy between methods.
Conclusion
The difference between methods regarding Delta% BF was statistically significant, but it was of small magnitude. However, with increasing Delta% BF, increasing discrepancies were observed, implying that the BIA equipment may have limited validity for detecting larger fat losses. Both clinicians and researchers may benefit from awareness of this potential limitation.
europepmc.org
以上显示的是最相近的搜索结果。 查看全部搜索结果