[HTML][HTML] Characterization of 244Cm neutron sources

R Radev, TD McLean - Applied Radiation and Isotopes, 2020 - Elsevier
There is a need to find a replacement for the 252 Cf sources currently used in Standards-
based performance testing of neutron instrumentation. This is a result of its relatively short …

The content of 250Cf and 248Cm in 252Cf neutron sources and the effect on the neutron emission rate

NJ Roberts, LN Jones - Radiation protection dosimetry, 2007 - academic.oup.com
One of the most common radionuclide neutron sources used for the calibration of detectors
is 252Cf. However, these sources also contain 250Cf, which is present in the material from …

Investigation of the implications of 250Cf and 248Cm in 252Cf neutron sources.

NJ Roberts, LN Jones - 2004 - eprintspublications.npl.co.uk
One of the most common radionuclide neutron sources used for calibration of detectors is
252Cf. However, these sources are not isotopically pure and also contain the neutron …

Neutron spectra, fluence and dose rates from bare and moderated Cf-252 sources

RP Radev - 2016 - osti.gov
A new, stronger 252Cf source (serial number SR-CF-3050-OR) was obtained from Oak
Ridge National Laboratory (ORNL) in 2014 to supplement the existing 252Cf sources which …

Characterization of 252Cf sources using high-resolution gamma spectroscopy

MM Watson, R Venkataraman, S Croft - Applied Radiation and Isotopes, 2021 - Elsevier
Californium-252 is used as a neutron calibration source for passive neutron correlation
counting. Source age and isotopic information are needed to make decay corrections to the …

Time-dependent multiplicity for Cf-252 neutron source

X Liu, Y Shi, J Li - Applied Radiation and Isotopes, 2023 - Elsevier
A Cf-252 neutron source is widely used for testing and calibrating neutron multiplicity
counters. General equations for calculating the time-dependent strength and multiplicity of …

Curium-248 standard neutron source

VM Radchenko, MA Ryabinin, NN Andreytchuk… - Applied Radiation and …, 2000 - Elsevier
A new standard neutron source based on curium-248 has been developed, prepared, and
certified. The curium-248 isotope is more long-lived than californium-252. The active core of …

Characterization of a neutron calibration field with 241Am− Be source using Bonner sphere spectrometer

TN Le, HN Tran, QN Nguyen, G Van Trinh… - Applied Radiation and …, 2018 - Elsevier
This paper presents the characterization of a neutron calibration field of a 241 Am− Be
source using Bonner sphere spectrometer. The characterization of the neutron field in terms …

Californium-252 neutron sources for industrial applications

AR Boulogne, JP Faraci - Nuclear Technology, 1971 - Taylor & Francis
Californium-252 makes an intense neutron point source that emits 2.34× 1012 n/(sec g)
through spontaneous fission. Sources are being prepared to investigate the value of this …

The multipurpose 14-MeV neutron source at Bratislava

J Pivarč, S Hlaváč - Nuclear science and engineering, 1990 - Taylor & Francis
A multipurpose 14-MeV neutron source based on the T (d, n) 4 He reaction is under
construction in Bratislava. Its basic purpose is to produce intense and pulsed beams of 14 …