Accuracy of a continuous blood pressure monitor based on arterial tonometry.

T Sato, M Nishinaga, A Kawamoto, T Ozawa… - …, 1993 - Am Heart Assoc
A validation study of the continuous noninvasive tonometric blood pressure monitor called
JENTOW was performed in 20 normotensive subjects and 10 hypertensive patients …

Validation of an automated arterial tonometry monitor using Association for the Advancement of Medical Instrumentation standards.

EA Zorn, MB Wilson, JJ Angel, J Zanella… - Blood pressure …, 1997 - europepmc.org
BACKGROUND: Arterial tonometry is a noninvasive technique for monitoring the arterial
blood pressure in a continuous manner. Real-time arterial blood pressure measurements …

Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?

MR Nelson, J Stepanek, M Cevette, M Covalciuc… - Mayo Clinic …, 2010 - Elsevier
The arterial pulse has historically been an essential source of information in the clinical
assessment of health. With current sphygmomanometric and oscillometric devices, only the …

Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking

LM Van Bortel, EJ Balkestein… - Journal of …, 2001 - journals.lww.com
Objectives Pulse pressure is not constant throughout the arterial tree. Use of pulse pressure
at one arterial site as surrogate for pulse pressure at another arterial site may be erroneous …

Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia.

O Kemmotsu, M Ueda, H Otsuka, T Yamamura… - …, 1991 - europepmc.org
Arterial tonometry is a technique used to measure arterial blood pressure noninvasively. The
authors developed a new tonometer system containing an array of 15 piezoresistive …

Development and modelling of arterial applanation tonometry: a review

K Matthys, P Verdonck - Technology and Health Care, 2002 - content.iospress.com
Arterial tonometry allows non-invasive and continuous registration of the arterial pressure
waveform, by applanating (flattening) a superficial artery supported by bone with an external …

Blood pressure measurement by arterial tonometry in controlled hypotension

O Kemmotsu, M Ueda, H Otsuka… - Anesthesia & …, 1991 - journals.lww.com
A newly developed arterial tonometer enabled us to measure the blood pressure waveforms
in addition to determining systolic and diastolic pressures noninvasively and continuously …

Methods for assessing blood pressure values in humans.

G Mancia - Hypertension, 1983 - Am Heart Assoc
In clinical medicine and epidemiology, measurements of blood pressure largely rely upon
the use of cuff inflation and Korotkoff sounds. Although still the most practical, this method …

24-hour blood pressure monitoring: evaluation of Spacelabs 5300 monitor by comparison with intra-arterial blood pressure recording in ambulant subjects

R Casadei, G Parati, G Pomidossi… - Journal of …, 1988 - journals.lww.com
The accuracy of 24-h blood pressure values obtained by ambulatory monitoring via the
Spacelabs 5300 device was evaluated by comparison with simultaneous 24-h intra-arterial …

Pulse pressure amplification, pressure waveform calibration and clinical applications

D Agnoletti, Y Zhang, P Salvi, C Borghi, J Topouchian… - Atherosclerosis, 2012 - Elsevier
Obtaining pulse pressure non-invasively from applanation tonometry requires the calibration
of pressure waveform with brachial systolic and diastolic blood pressure. In the literature …