Influence of IOP measurement through the wrong eyepiece of the slit lamp on Goldmann applanation tonometry

T Kubota, T Nagata, A Tawara… - European journal of …, 2008 - journals.sagepub.com
Purpose This study examined whether intraocular pressure (IOP) measurements through the
wrong eyepiece of the slit lamp may be a source of error. Methods Seven skilled observers …

Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer

QK Farhood - Clinical Ophthalmology, 2012 - Taylor & Francis
Purpose Tonometry, or measurement of intraocular pressure (IOP), is one of the most
important examination procedures in ophthalmic clinics, and IOP is an important parameter …

Impact factors on intraocular pressure measurements in healthy subjects

T Theelen, CFM Meulendijks, DEM Geurts… - British journal of …, 2004 - bjo.bmj.com
Aim: To evaluate whether intraocular pressure (IOP) calculation by applanation tonometry is
determined more essentially by the subject's neck position or by neck constriction. Methods …

[HTML][HTML] Disposable devices for measuring intraocular pressure: a clinical study to assess their accuracy

A Bhatnagar, AK Gupta - Eye, 2005 - nature.com
Aims We conducted a study to compare the accuracy of two commercially available
disposable tonometry devices (the acrylic biprism, Tonosafe™ and the silicone shield …

[HTML][HTML] Evaluation of the new digital Goldmann applanation tonometer for measuring intraocular pressure

Y Sakaue, J Ueda, M Seki, T Tanaka… - Journal of …, 2014 - hindawi.com
Purpose. To compare a new digital Goldmann applanation tonometer (dGAT) that measures
intraocular pressure (IOP) in 0.1 mmHg increments to a standard Goldmann applanation …

Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population

P Fernandes, JA Díaz‐Rey, A Queiros… - Ophthalmic and …, 2005 - Wiley Online Library
The aim of this study was to evaluate the accuracy of measurement of intraocular pressure
(IOP) using a new induction/impact rebound tonometer (ICare®) in comparison with the …

Comparative study of intraocular pressure measurements by Goldmann applanation tonometer, noncontact tonometer and TonoPen

BM Ceská, K Ferrova, A Filous… - Ceska a slovenska …, 2012 - europepmc.org
Methods NOT was assessed in 106 eyes of 106 subjects aged 7-77 years (average 34.3+/-
17.1 years). NOT was measured at the same moment with BT, TP and AT. The obtained data …

Accuracy of the Tonosafe disposable tonometer head compared to the Goldmann tonometer alone

P Kim, S Lertsumitkul, M Clark… - Clinical & …, 2004 - Wiley Online Library
Purpose: To assess the accuracy of the Tonosafe disposable prism tonometer head via a
randomised controlled prospective trial. Methods: The intraocular pressure (IOP) of 69 …

Evaluation of accuracy in Goldmann and perkins applanation tonometry

JC Hartley, J Song - Investigative Ophthalmology & Visual …, 2006 - iovs.arvojournals.org
Purpose:: To evaluate the accuracy of intraocular pressure (IOP) measurements with
Goldmann slit–lamp mounted applanation tonometry compared to Perkins hand–held …

Clinical comparison of two intraocular pressure measurement methods: SmartLens dynamic observing tonography versus Goldmann

R Troost, A Vogel, S Beck, O Schwenn, F Grus… - Graefe's archive for …, 2001 - Springer
Purpose: To compare intraocular pressure measurements obtained with SmartLens, a
gonioscopic contact lens, to those from Goldmann applanation tonometry. Methods: Eighty …