Effect of corneal thickness on the accuracy of intraocular pressure measurement in rabbits after excimer laser photoablation

J Stahl, S Vold - Journal of Cataract & Refractive Surgery, 2000 - journals.lww.com
Purpose: To determine whether intraocular pressure (IOP) measurements using
pneumotonometry and Tono-Pen tonometry are accurate after excimer laser photoablation …

Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia

S Hamed-Azzam, D Briscoe, O Tomkins… - International …, 2013 - Springer
Intraocular pressure is affected by corneal thickness and biomechanics. Following ablative
corneal refractive surgery, corneal structural changes occur. The purpose of the study is to …

Analysis of intraocular pressure and corneal thickness after laser in situ keratomileusis

Y Pan, Y Zhang, J Lian, K Wang - … Zhonghua yan ke za Zhi] Chinese …, 1999 - europepmc.org
Objective To analyze the changes and relationship of the intraocular pressure (IOP) and the
corneal thickness (CT) after laser in situ keratomileusis (LASIK). Methods This prospective …

Reduction in intraocular pressure after laser in situ keratomileusis

HJ Park, KB Uhm, C Hong - Journal of Cataract & Refractive Surgery, 2001 - Elsevier
PURPOSE: To investigate whether intraocular pressure (IOP) measured on the nasal side is
affected after laser in situ keratomileusis (LASIK). SETTING: The Glaucoma Service, Dr …

Accuracy and predictability of the compensatory function of Orbscan II in intraocular pressure measurements after laser in situ keratomileusis

DH Lee, S Seo, SC Shin, EH Chung… - Journal of Cataract & …, 2002 - Elsevier
Purpose: To evaluate the usefulness of the compensatory function of Orbscan II (Orbtek,
Bausch & Lomb) for measuring postoperative intraoperative pressure (IOP) in laser in situ …

The Effect of Excimer Laser Photorefracti* ve Keratectomy on Intraocular Pressure Measurements Using the Goldmann Applanati-on Tonometer

PG Mardelli, LW Piebenga, MM Whitacre… - Ophthalmology, 1997 - Elsevier
Purpose: The authors determined whether photorefractive keratectomy (PRK) affects
Goldmann applanation readings in human eyes. Methods: The intraocular pressure (10P) of …

Evaluation of intraocular pressure change after laser in situ keratomileusis using the pressure phosphene tonometer

S Naruse, K Mori, M Kojo, O Hieda… - Journal of Cataract & …, 2004 - Elsevier
Purpose: To evaluate the applicability of pressure phosphene tonometry in measuring
intraocular pressure (IOP) after laser in situ keratomileusis (LASIK). Setting: Baptist Eye …

Tonometry after laser in situ keratomileusis treatment

S Duch, A Serra, J Castanera, R Abos… - Journal of …, 2001 - journals.lww.com
Purpose To assess the reliability of intraocular pressure measurements by Goldmann
applanation tonometry versus pneumotonometry after laser in situ keratomileusis for myopia …

Intraocular pressure assessment in both eyes of the same patient after laser in situ keratomileusis

SY Hsu, MS Chang, CJ Lee - Journal of Cataract & Refractive Surgery, 2009 - Elsevier
PURPOSE: To measure intraocular pressure (IOP) after laser in situ keratomileusis (LASIK)
in both eyes of the same patient and analyze the correlation between IOP measurement and …

Comparison of intraocular pressures after myopic laser-assisted subepithelial keratectomy: tonometry-pachymetry, Goldmann applanation tonometry, dynamic contour …

KE Han, H Kim, NR Kim, I Jun, EK Kim - Journal of Cataract & Refractive …, 2013 - Elsevier
PURPOSE: To compare intraocular pressure (IOP) measurements using a new tonometer–
pachymeter device (Tonopachy), Goldmann applanation tonometry (GAT), dynamic contour …