Comparison of central pressure estimates obtained from SphygmoCor, Omron HEM-9000AI and carotid applanation tonometry

JG Kips, AE Schutte, SJ Vermeersch… - Journal of …, 2011 - journals.lww.com
Background The Omron HEM-9000AI is the first automated tonometer to provide an estimate
of central SBP (cSBP), which is considered to be more predictive of cardiovascular events …

Carotid tonometry versus synthesized aorta pressure waves for the estimation of central systolic blood pressure and augmentation index

P Segers, E Rietzschel, S Heireman… - American journal of …, 2005 - academic.oup.com
Objective: To assess the interchangeability of carotid tonometry and synthesized aorta
pressure waveforms for estimating central systolic blood pressure (SBP) and augmentation …

The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography

A Siebenhofer, CRW Kemp, AJ Sutton… - Journal of human …, 1999 - nature.com
Aim: Sphygmocardiography via applanation tonometry is a non-invasive, bedside
technology which utilises tonometric analysis of the radial artery pulse wave and …

Comparison of estimates of central systolic blood pressure and peripheral augmentation index obtained from the Omron HEM-9000AI and SphygmoCor systems

CJ Richardson, KM Maki-Petaja, BJ McDonnell… - Artery research, 2009 - Springer
Central blood pressure is increasingly considered to be more predictive of cardiovascular
events than peripheral pressure. Central systolic pressure (cSBP) can be estimated from the …

Clinical assessment of central blood pressure

H Miyashita - Current hypertension reviews, 2012 - ingentaconnect.com
Central aortic blood pressure (CBP) is increasingly considered a better cardiovascular
prognostic marker than conventional cuff brachial blood pressure. Because CBP cannot be …

Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures

GC Cloud, C Rajkumar, J Kooner, J Cooke… - Clinical …, 2003 - portlandpress.com
Central arterial pressure, measured close to the heart, may be of more patho-physiological
importance than conventional non-invasive cuff blood pressure. The technique of …

[HTML][HTML] Arterial pressure: agreement between a brachial cuff-based device and radial tonometry

CM Park, O Korolkova, JE Davies, KH Parker… - Journal of …, 2014 - journals.lww.com
Objectives: Aortic (central) blood pressure (BP) differs from brachial BP and may be a
superior predictor of cardiovascular events. However, its measurement is currently restricted …

Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure

JI Davies, MM Band, S Pringle, S Ogston… - Journal of …, 2003 - journals.lww.com
Background The Sphygmocor system purports to be able to assess ascending aortic blood
pressure using a transfer function. It has been shown to be accurate when data obtained …

Evaluation of a novel sphygmomanometer, which estimates central aortic blood pressure from analysis of brachial artery suprasystolic pressure waves

ACW Lin, A Lowe, K Sidhu, W Harrison… - Journal of …, 2012 - journals.lww.com
Background: Central arterial pressure is a better predictor of adverse cardiovascular
outcomes than brachial blood pressure, but noninvasive measurement by applanation …

Noninvasive assessment of local pulse pressure: importance of brachial-to-radial pressure amplification

F Verbeke, P Segers, S Heireman, R Vanholder… - …, 2005 - Am Heart Assoc
The advocated SphygmoCor procedure uses a radial-to-aorta transfer function with
calibration on brachial instead of radial artery pressure to assess the central pulse pressure …